| 2014-09-26 17:24:19 | RESIDENTIAL (R2) FLOORING, RE-SUBMITTAL BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- SOUND INSULATION PROFLEX MSC 90 INFORMATION | | | SUBMITED: | | | | | | A) SOUND TRANSMISSION TEST (ASTM E 90) AND IMPACT SOUND | | | TRANSMISSION TEST (ASTM E 492) INFORMATION SUBMITTED IS | | | FOR AN 8" CONCRETE SLAB FLOOR-CEILING ASSEMBLY WITH A | | | SUSPENDED CEILING SYSTEM. I CAN ISSUE THE PERMIT IF YOU | | | CONFIRM THAT THIS IS THE TYPE OF FLOOR CEILING ASSEMBLY | | | FOR THE PROPOSED INSTALLATION. OTHERWISE, SUBMITT | | | PROPER TESTING INFORMATION MATCHING THE PROPOSED | | | INSTALLATION AS REQUIRED BY SEC. 1207.2 AND 1207.3 OF | | | 2010 FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|