| 2015-03-27 15:05:22 | PLAN REVIEW COMMENTS |
| | |
| | 3RD REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | BUILDING |
| | |
| | 1) REVISE COMPONENT AND CLADDING PRESSURES FOR THE |
| | WINDOWS AND DOORS TO CORRESPOND WITH THE INCREASED |
| | PRESSURES FOR EXPOSURE D. FBC - R301.2.1 THE EXPOSURE |
| | CATEGORY WAS CHANGED FROM C TO D, BUT THE PRESSURES |
| | WERE NOT CHANGED. |
| | |
| | 2) SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION |
| | SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER |
| | CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS |
| | 402 OR 405. (ENERGY CALCS.) THE PLANS SPECIFY THAT THE |
| | AIR HANDLER FOR THE ADDITION IS LOCATED IN THE ATTIC. |
| | ENERGY FORM 402 CAN NOT BE USED WHEN THE AIR HANDLER IS |
| | LOCATED IN THE ATTIC. |
| | |
| | 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE SUBMITTALS |
| | FOR THE ASPHALT SHINGLE ROOFING. |
| | |
| | 4) FBC R704 IN ORDER TO PROVIDE FOR INSPECTION FOR |
| | TERMITE INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL |
| | COVERINGS AND FINAL EARTH GRADE ON THE EXTERIOR OF A |
| | BUILDING SHALL NOT BE LESS THAN 6 INCHES (152 MM). THE |
| | STUCCO STOP / WEEP SCREED IS REQUIRED TO BE 6 INCHES |
| | ABOVE FINAL EXTERIOR GRADE. |
| | |
| | IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE |
| | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER |
| | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN |
| | ADDRESSED. |
| | |
| | |
| | |
| | |
| | |
| | |