| Plan Review Notes For Permit 14090577 |
| Permit Number |
14090577 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-09-18 11:42:06 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC 2010 RESIDENTIAL 301, FBC 2010 BUILDING 1609 | | | (RESISTANCE TO WIND LOADS) | | | | | | 1. FOR THE FLAT DECK ROOF, INDICATE WHICH FASTENING | | | OPTION WITHIN THE APPROVED ASSEMBLY IS PROPOSED. | | | | | | 2. SEE GENERAL LIMITATION NUMBER 7 ON THE LAST PAGE OF | | | THE MIAMI DADE NOA. FASTENER DENSITIES SHALL BE | | | INCREASED IN COMPLIANCE WITH RAS 117. CALCULATIONS | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR | | | REGISTERED ROOF CONSULTANT IS REQUIRED. | | | | | | PLEASE NOTE THAT THE 400 SQUARE FOOT EXEMPTION TO | | | ENGINEERING IS A PALM BEACH COUNTY EXEMPTION NOT | | | APPLICABLE IN THE CITY OF WEST PALM BEACH. | | | | | | | | | |
|