| Date |
Text |
| 2014-09-24 09:26:27 | BUILDING PLAN REVIEW |
| | PERMIT: 14090513 |
| | ADD: 701 VILLAGE BLVD. |
| | CONT: RAPP CONSTRUCTION |
| | TEL: (561)842-3299 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED, SEPT. 24/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT IS FOR THE INSTALATION OF AN AUTOMATIC |
| | TELLER MACHINE AND ON SHEET A1 & A2 THE PLANS PROVIDE |
| | VARIOUS ELEVATIONS AND MEASUREMENTS BUR THE PLANS DO |
| | NOT CLEARLY SHOW COMPLIANCE WITH SECTION 2010 FL |
| | ACCESSIBILITY CODE 707.3 OPERABLE PARTS. |
| | OPERABLE PARTS SHALL COMPLY WITH 309. UNLESS A CLEAR OR |
| | CORRECT KEY IS PROVIDED, EACH OPERABLE PART SHALL BE |
| | ABLE TO BE DIFFERENTIATED BY SOUND OR TOUCH, WITHOUT |
| | ACTIVATION. |
| | |
| | 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE |
| | OR MORE OF THE REACH RANGES SPECIFIED IN 308. |
| | |
| | 308.2.1FRONT APPROACH. UNOBSTRUCTED. WHERE A FORWARD |
| | REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE |
| | 48 INCHES (1220 MM) MAXIMUM AND THE LOW FORWARD REACH |
| | SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 308.3.1 SIDE APPROACH. UNOBSTRUCTED. WHERE A CLEAR |
| | FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN |
| | ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH |
| | SIDE REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM AND THE |
| | LOW SIDE REACH SHALL BE 15 INCHES (380 MM) MINIMUM |
| | ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |