| Plan Review Notes For Permit 14090389 |
| Permit Number |
14090389 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-11-18 12:11:52 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE SEE BUILDING COMMENTS, WILL STAMPED APPROVED | | | WHEN CORRECTED IF NO ADDTIONAL CHANGES. | | 2014-09-15 15:23:37 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | ALL EXIT PATHS AND CAPACITIES FROM ALL FLOOR LEVELS | | | SHALL BE CLEARLY IDENTIFIED AND INDICATED. | | | | | | SHEET A-O SHOWS OCCUPANCY LOADS THAT CAN'T BE CONFIRMED | | | WITH THE INFORMATION PROVIDED. A LIFE SAFETY PLAN SHALL | | | BE SUBMITTED SHOWING ALL EXIT PATHWAYS, FROM ALL | | | FLOORS, WITH OCCUPANT LOADS, LEADING TO A PUBLIC WAY. | | | THE EXITS DISCHARGES ON THE 1ST FLOOR SHALL BE | | | IDENTIFIED (WITH DIMENSIONS) AND SHALL LEAD TO A PUBLIC | | | WAY. | | | | | | SHEET A-3 SHOWS AN EXIT DOOR WITH AN EXIT CAPACITY OF | | | 165 AND THE STAIR EXIT CAPACITY OF 200. THE EXIT | | | CAPCITY CAN ONLY BE MEASURED AT THE NARROWEST POINT, | | | 165. IT IS UNCLEAR WHAT THE PROPOSED TOTAL IS USING. | | | | | | SHEET A-3 DOES NOT SHOW THE SECOND EXIT FROM THE THIRD | | | OR SECOND FLOOR AND THE EXIT CAPACITIES CALCULATIONS. | | | | | | OCCUPANT LOADS CAN NOT BE VERIFIED OR APPROVED AT THIS | | | TIME WITHOUT FLOOR AND SEATING PLANS AND EXIT CAPACITY | | | APPROVAL. | | | |
|