| Plan Review Notes For Permit 14090347 |
| Permit Number |
14090347 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2014-10-30 13:13:59 | WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 1) SUBMIT TWO COMPLETE COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS/INSTALLATION MANUALS. THE INFORMATION | | | YOU HAVE SUBMITTED IS INCOMPLETE. | | | 2) THE EXISTING PLUMBING RISER HAS A FLAT DRY VENT FOR | | | THE MOST UPSTREAM CHAIR. THE VENT CONNECTION OF A DRY | | | VENT TO A HORIZONTAL DRAIN SHALL CONNECT ABOVE THE | | | CENTERLINE OF THE HORIZONTAL DRAIN PIPE. 2010 FPC | | | SEC.905.3. | | | 3) THE PLUMBING INSTALLATION FOR THE ADDED CHAIRS | | | CANNOT BE INSTALLED AS DESIGNED. CONSIDER A CIRCUIT | | | VENT SYSTEM IN ACCORDANCE W/ 2010 FPC SEC.911. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|