2014-10-10 08:36:02RESIDENTIAL (R3) ALTERATION AND ADDITION, BUILDING
 REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- SHEET A-02:
 A) MASTER BEDROOM WINDOW "F" ON THE WINDOW SCHEDULE ON
 SHEET A-04 STATES "MUST MEET EGRESS REQ FOR 5 SF MIN
 CLR OPNG". THE MIN. CLEAR OPENING ON A SECOND FLOOR
 BEDROOM WINDOW IS 5.7 S.F.. SEC. R310.1.1 OF 2010
 FBC-RESIDENTIAL. REVISE SPECIFICATIONS AND PROVIDE
 MANUFACTURER'S CUT SHEETS SHOWING THAT THE PROPOSED
 WINDOW SIZE WILL PROVIDE THE MIN. REQUIRED CLEAR
 OPENINGS (WIDTH, HEIGHT AND TOTAL CLEAR OPENING). SEC.
 107.2.1.3 OF CITY AMENDMENTS TO FBC.
  
 B) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 NEW AWNINGS (AND RELOCATED AWNINGS). SEC. R301 OF 2010
 FBC-RESIDENTIAL.
 ***NOTE: OR SPECIFY IF COMPLETE INFORMATION WILL BE
 PROVIDED UNDER A SEPARATE PERMIT.
  
 C) NEW SECOND BEDROOM LOCATED ON THE SECOND LEVEL. SHOW
 COMPLIANCE THAT THE WINDOWS COMPLY WITH THE EGRESS
 REQUIREMENTS (HEIGHT, WIDTH AND TOTAL CLEAR OPENING) OF
 SEC. R310 OF 2010 FBC-RESIDENTIAL.
  
 2- PLANS ARE MISSING INFORMATION REGARDING THE EXTERIOR
 WALL COVERING:
 A) PROVIDE DETAILS/SPECIFICATIONS FOR THE STUCCO FINISH
 THICKNESS SHOWING COMPLIANCE WITH TABLE R702.1(1) OF
 2010 FBC-RESIDENTIAL.
  
 B) PROVIDE DETAILS/SPECIFICATIONS FOR THE STUCCO BOND
 BREAK SHOWING COMPLIANCE WITH SEC. R703.6.3 OF 2010
 FBC-
  
 3- SHEET A-03: SPECIFY SCUPPERS SIZES AND REVISE
 LOCATION OF EMERGENCY OVERFLOW SCUPPER TO SHOW
 COMPLIANCE WITH SEC. R903.4.1 OF 2010 FBC-RESIDENTIAL.
 EMERGENCY SCUPPER SHALL BE LOCATED CLOSE TO THE
 VERTICAL DOWNSPOUT.
  
 4- PROPOSED WEST ELEVATION ON SHEET A-05: SPECIFY ATTIC
 VENT SIZES AND CLARIFY HOW THE TWO "CLAY ATTIC VENTS"
 ARE GOING TO PROVIDE CROSS VENTILATION AS REQUIRED BY
 SEC. R806 OF 2010 FBC-RESIDENTIAL.
 ***NOTE: NEW 2X12 RAFTERS DON'T ALLOW CROSS VENTILATION
 AT THE NEW ROOF AREA.
  
 5- SHEET S-4:
 A) PROVIDE THE DESIGN WINDOWS PRESSURES FOR ZONE #5.
 ONLY THE ZONE #4 WERE PROVIDED. SEC. R301 OF 2010
 FBC-RESIDENTIAL.
 B) PROVIDE THE DESIGN PRESSURES FOR DOORS TO BE
 REPLACED. SEC. R301.
 C) SPECIFY DIMENSION "Z" ON THE FLAT ROOF .
 ***NOTE: THIS DIMENSION IS 4'-0" IN ALL CASES. SEE NOTE
 "A" OF FIGURE R301.2(7) OF 2010 FBC-RESIDENTIAL.
 C) PROVIDE THE DESIGN PRESSURES FOR SKYLIGHTS TO BE
 REPLACED. COORDINATE WITH ITEM #5(C) ABOVE.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) SKYLIGHTS. NOA 13-1217.24 SUBMITTED WAS SUPERSEDED
 BY MIAMI-DADE. VISIT THE MIAMI-DADE WEBSITE AND
 DOWNLOAD CURRENT NOA.
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR. OR PROVIDE THE FLORIDA PRODUCT APPROVAL
 NUMBER ADJACENT TO EACH CONNECTOR SPECIFIED ON PLANS.
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS (INCLUDING THE ROOFING, SKYLIGHTS). AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 8- FLAT ROOF MODIFIED BITUMEN NOA 13-0424.14 SUBMITTED:
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 SUBMITTED. NEED THE CALCULATIONS TO MEET THE DESIGN
 PRESSURES REQUIRED BY SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 **** PLEASE REMOVE AND REPLACE ANY REVISED SHEET.
 **** PLEASE PROVIDE PLANS WITH PALM BEACH COUNTY IMPACT
 FEES STAMP AND PROVIDE COPY OF PAID RECEIPT IF FEES ARE
 DUE.
  