| 2014-09-13 11:18:11 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 |
| | [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2010 |
| | |
| | TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED |
| | |
| | 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING |
| | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR |
| | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS |
| | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR |
| | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. |
| | IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST, |
| | PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED |
| | THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE |
| | GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL |
| | NOT BE ALTERED. |
| | |
| | PLEASE PROVIDE A COPY OF THE TEST REPORT. |
| | |
| | 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN |
| | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC |
| | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN |
| | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN |
| | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH |
| | ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART |
| | OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN |
| | DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW |
| | IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT |
| | BELOW WILL NOT BE ALTERED. |
| | |
| | PLEASE PROVIDE A COPY OF THE TEST REPORT. |
| | |
| | 3. FBC 603.1, A LETTER FROM THE MANUFACTURER COMMITTING |
| | TO TEST THIS PRODUCT TO ASTM E84 OR UL723 HAS BEEN |
| | RECEIVED; THIS PERMIT WILL BE ISSUED WITH PROVISO THAT |
| | THE TEST RESULT BE SENT VIA EMAIL WHEN AVAILABLE. THE |
| | LETTER MAKES REFERENCE TO CLASS 1 AND CLASS 2. PLEASE |
| | BE ADVISED THAT ASTM E84 FLAME SPREAD REQUIREMENT FOR |
| | THIS APPLICATION IS 200 OR LESS (THE LEAST STRINGENT OF |
| | THE REQUIREMENTS IN 603.1). IT IS ACCEPTED THAT YOU |
| | HAVE A REASONABLE EXPECTATION THAT THE PRODUCT WILL |
| | HAVE A TEST RESULT LESS THAN 200. |
| | |
| | 4. VALUE IS TO INCLUDE LABOR AND MATERIALS, FBC 109. |
| | |
| | |
| | |
| | |
| | |