| 2014-10-14 19:04:36 | |
| | |
| | 1ST REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | BUILDING |
| | |
| | 1) SHEETS A1.1 SITE PLAN AND D2.1 DEMOLITION PLAN ARE |
| | MISSING FROM THE PACKAGE. THERE IS A SEPARATE PERMIT |
| | FOR THE DEMOLITION WITH THESE SHEETS, HOWEVER, IT WOULD |
| | HELP CLARIFY THE WORK IF THESE PLAN SHEETS ARE INCLUDED |
| | IN THIS SUBMITTAL. THEY ARE ALSO LISTED IN THE LIST OF |
| | DRAWINGS ON SHEET A0.1. FBC 107.2.1 |
| | |
| | 2) FBC 107.3.4 - THE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 ARE |
| | REQUIRED TO REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. |
| | |
| | 3) FBC 107.3.4 & DCA RULE 9N-3 - SUBMIT TWO SETS OF |
| | PRODUCTS APPROVALS FOR THE IMPACT RATED EXTERIOR ARCHED |
| | TOP IN-SWING ENTRY DOOR #101 AND THE IMPACT RATED |
| | EXTERIOR DOUBLE OUT-SWING FOYER DOOR #102. |
| | |
| | 4) FBC 107.2.1 - CLARIFY THE EXTERIOR DOOR #105 AT THE |
| | FAMILY ROOM. ON SHEET A3.2 IT IS SPECIFIED AS CASEMENT |
| | WINDOWS. THE PRODUCT APPROVAL FOR CASEMENT WINDOWS THAT |
| | WAS SUBMITTED HAS MAXIMUM UNIT HEIGHT OF 71-7/8". THE |
| | UNIT HEIGHT FOR THIS OPENING IS 85" ON THE PLANS. |
| | |
| | 5) INSTALLATION DRAWINGS FOR KML FIXED WINDOWS WERE |
| | SUBMITTED. THE FL NUMBER IS NOT LISTED ON THE DRAWINGS. |
| | SUBMIT TWO COPIES OF THE COVERSHEET WITH THE FL# THAT |
| | LISTS THESE DRAWINGS. ALSO INDICATE WHERE THIS WINDOW |
| | WILL BE INSTALLED. NOTE: PRODUCT APPROVALS FOR AN |
| | ANDERSON FIXED WINDOW WERE ALSO SUBMITTED. ARE THESE |
| | BOTH FOR THE ARCHED FIXED GLASS WINDOWS ABOVE THE GAME |
| | ROOM DOORS. FBC 107.2.1 |
| | |
| | 6) SUBMIT THE PRODUCT APPROVALS FOR THE EXTERIOR DOORS |
| | AND WIND THAT ARE TO BE RE-INSTALLED IN DIFFERENT |
| | LOCATIONS FBC 107.3.4 & DCA RULE 9N-3 |
| | |
| | 7) IN ORDER TO SPEED PLAN REVIEW TIMES AND PROVIDE |
| | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER |
| | INDICATING HOW THE REVIEW COMMENTS HAVE BEEN ADDRESSED. |
| | |
| | |
| | |