2014-09-10 16:26:301ST REVIEW: FBC 2010
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM
 CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE
 PLAN; FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS
 LAYOUT; ALL FENESTRATION PENETRATIONS;
 FLASHING; AND ROUGH OPENING DIMENSIONS; AND ALL
 EXTERIOR ELEVATIONS:
  
 PROVIDE STRUCTURAL DETAILS AND CLARIFY CONFLICTS IN THE
 PLAN AS FOLLOWS:
  
 DETAIL THE RETROFIT OPENINGS FOR WINDOWS IDENTIFIED TO
 BE RELOCATED ON SHEET A-3 & A-4.
 PROVIDE DOCUMENTTATION FOR "WINDOWS TO BE RELOCATED" TO
 DEMONSTRATE SUCH WINDOWS COMPLY WITH THE FLORIDA
 BUILDING CODE.
 DETAIL THE CLOSING OF OPENING OF FORMER WINDOWS.
 DETAIL THE NEW OPENINGS FOR NEW WINDOWS AND DOORS ON
 SHEET A-3 &A-4.
 CLARIFY THE ROOF SHEATHING TYPE. THE PLAN CONLICTS
 INDICATING 1/2" AND 5/8."
 CLARIFY ALL SHEATHING NAILING SPECIFICATIONS. ARE RING
 SHANK NAILS INTENDED? NOTES REFER TO A DETAIL WHICH
 APPARENTLY IS NOT UPON THE PLAN.
 CLARIFY THE PORCH CORNER POST. IS IT A 3" PIPE, OR A
 6X6 WOOD POST?
  
 THANK YOU,
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710