Plan Review Notes
Plan Review Notes For Permit 14081149
Permit Number 14081149
Review Stop B
Sequence Number 1
Notes
Date Text
2014-08-27 12:31:45****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
 [email protected]
  
 FBC FLORIDA BUILDING CODE 2010
  
 TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED
  
 1. THE IIC REPORT INCLUDES A DROPPED CEILING. THE STC
 REPORT WAS NOT PROVIDED.
  
 PLEASE REVISE PLAN - DOES THE SPACE (UNIT) BELOW THE
 RENOVATED AREA HAVE A DROPPED CEILING IN THIS AREA? IF
 IT DOES, REVISE PLAN TO INDICATE THAT THERE IS A
 DROPPED CEILING BELOW. ALSO SUBMIT THE STC TEST REPORT,
 FBC 1207.2.
  
 IF THE UNIT BELOW DOES NOT HAVE A DROPPED CEILING, PER
 MANUFACTURER THIS PRODUCT (MSC90) DOES NOT MEET THE
 MINIMUM RATING OF 50 WITHOUT THE DROPPED CEILING.
 MANUFACTURER OF PROFLEX RECOMMENDED RCU250 IF THERE IS
 NO DROPPED CEILING BELOW.
  