| Plan Review Notes For Permit 14081068 |
| Permit Number |
14081068 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-08-25 17:59:42 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ENGINEER TO REVISE RAS 117 CALCULATIONS. NOA | | | 13-05614.12 SUBMITTED SHOWS BASE SHEET FASTENING OPTION | | | #1 WITH THREE ROWS OF RING SHANK NAILS IN THE CENTER OF | | | THE SHEET. ENGINEER CALLED FOR TWO ROWS. REVISE | | | CALCULATIONS AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS | | | TO FBC. | | | | | | 2- PROVIDE TWO COPIES OF SIGNED AND SEALED RAS 117 | | | CALCULATIONS. SEC. 107.1 OF CITY AMENDMENTS TO FBC. | | | | | | 3- PROPERTY IS LOCATED IN THE HISTORIC DISTRICT. NEEDS | | | HISTORIC APPROVAL. PERMIT APPLICATION CALLS TO REPLACE | | | CONCRETE TILE WITH SHINGLES. THIS MAY NOT BE ALLOWED BY | | | HISTORIC. IF HISTORIC REQUIRES CONCRETE TILE, THEN | | | VALUATION DECLARED IN THE PERMIT APPLICATION NEEDS TO | | | BE ADJUSTED ACCORDINGLY. SEC. 109.3 CITY AMENDMENTS TO | | | FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|