| 2015-03-01 08:14:55 | 1)THE OCCUPANCY NOTED ON THE PLANS IS SHOWN AS |
| | EDUCATIONAL. TABLE 403.1 OF THE FL. PLUMBING CODE |
| | REQUIRES SEPARATE FACILITIES FOR THE MALES AND FEMALES. |
| | A MINIMUM OF ONE WATER CLOSET AND ONE LAVATORY SHALL BE |
| | PROVIDED FOR THE MALES AND ALSO THE FEMALES. A SERVICE |
| | SINK IS ALSO REQUIRED AND A DRINKING FOUNTAIN. |
| | 2) A MINIMUM OF TWO DRINKING FOUNTAINS SHALL BE |
| | SUPPLIED IN ACCORDANCE WITH THE 2010 FL. ACCESSIBILITY |
| | CODE SEC. 211.2 |
| | 3) THE BUILDING SHALL COMPLY WITH FL. STATUTE 553.415 |
| | AND SECTION 428 OF THE 2010 FL. BUILDING CODE. APPROVED |
| | PLANS AND SPECIFICATIONS SHALL BE EVIDENCED BY A LETTER |
| | OF CERTIFICATION FROM THE AGENCY AUTHORIZED TO PERFORM |
| | INSPECTIONS OF OR REVIEW PLANS FOR MANUFACTURED |
| | BUILDINGS AS PROVIDED IN FL. ADMIN. RULE 9B-1 PER THE |
| | 2010 FBC SEC.428.2, 428.4.2. |
| | 4) SHT. A1 SHOWS A CITY WATER CONNECTION TO THE TRAILER |
| | AND THERE IS ALSO AN 8 1/2' X 11' DRAWING STAPLED TO |
| | THE PLAN SHOWING THE SOURCE OF WATER BEING A RAIN |
| | BARREL. CLARIFY. IF A RAIN BARREL WILL BE THE WATER |
| | SOURCE, SUBMIT A COMPLETE PIPNG PLAN INCLUDING THE PUMP |
| | SHOWING HOW THE WATER WILL BE PIPED TO THE TRAILER AND |
| | HOW THE PRESSURE WILL BE MAINTAINED. WPB AMEND. TO 2010 |
| | FBC SEC. 107.2.1. |
| | 5) ONLY POTABLE WATER SHALL BE SUPPLIED TO PLUMBING |
| | FIXTURES THAT PROVIDE WATER FOR DRINKING , BATHING, OR |
| | CULINARY PURPOSES PER THE 2010 FPC SEC. 602.2. SIGNS |
| | SHALL BE POSTED AT ANY FIXTURE UTILIZING NON-POTABLE |
| | WATER THAT THE WATER IS NON-POTABLE AND NOT FOR DRINING |
| | PURPOSES. |
| | |
| | PLUMBING PLAN REVIEW |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | 561-805-6692 |
| | [email protected] |
| | |