| Plan Review Notes For Permit 14080885 |
| Permit Number |
14080885 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2014-10-14 11:39:38 | PLAN REVIEW COMMENTS | | | | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | BUILDING | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. SHEETS C-1 AND | | | E-1 ARE REQUIRED TO HAVE THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DRAWING. | | | | | | 2) FBC R301.2.1 SPECIFY THE METHOD OF ATTACHMENT THAT | | | WILL BE USED TO INSTALL THE CONCRETE ROOF TILE. IF A | | | ROOF TILE ADHESIVE IS USED SUBMIT TWO COPIES OF IT'S | | | PRODUCT APPROVALS THAT HAVE BEEN APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD. DCA RULE 9N-3 AND FBC 107.3.4.1 | | | | | | 3) ON SHEET S-2 THE EXPOSURE CATEGORY IS SPECIFIED AS | | | "D" . EXPOSURE CATEGORY "C" IS SPECIFIED ON SHEETS A-1 | | | AND A-2. THIS STRUCTURE IS LOCATED IN EXPOSURE C, THE | | | WINDLOAD PRESSURES ARE INCREASED IN EXPOSURE D. PLEASE | | | CORRECT. FBC R301.1.3 AND FBC R301.2.1.4.3 | | | | | | 4) THE PLANS INDICATE THAT THE LOCATION OF THE | | | SKYLIGHTS IS TO BE DETERMINED ON THE JOB. THE SKYLIGHTS | | | HAVE A DESIGN PRESSURE OF +60 PSF, -100 PSF. THEY WILL | | | NOT MEET THE UPLIFT PRESSURES OF THE CORNERS (ROOF ZONE | | | 3) FOR EXPOSURE D. FBC R301.1.3 |
|