| Plan Review Notes For Permit 14080813 |
| Permit Number |
14080813 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-09-15 09:38:06 | 1) INDICATE THE OCCUPANT LOAD FOR EACH MODULAR BUILDING | | | PER TABLE 1004.1.1 OF 2010 FBC. | | | 2) INDICATE ON THE PLAN HOW THE OCCUPANTS WILL HAVE | | | ACCESS TO THE REQUIRED SANITARY FACILITIES PER TABLE | | | 403.1 OF THE 2010 FL. PLUMBING CODE. FACILITIES SHALL | | | BE PROVIDIED FOR EACH SEX.FPC SEC.403.2. | | | 3) THE PATH OF TRAVEL TO SANITARY FACILITIES SHALL NOT | | | EXCEED 500 FEET PER THE FPC SEC.403.3.2. | | | 4) LOCATION OF THE SANITARY FACILITIES SHALL BE CLEARLY | | | DESIGNATED BY SIGNAGE COMPLYING WITH THE 2010 FPC | | | SEC.403.4, 403.4.1. | | | 5) ALL ROUTES PROVIDING ACCESS TO THE SANITARY | | | FACILITIES SHALL COMPLY W/ THE FLORIDA ACCESSIBILITY | | | CODE, ACCESSIBILITY. | | | 6) THE PLANS SHOW AN OPTIONAL RESTROOM INSIDE THE | | | BUILDING. IF THIS RESTROOM WILL BE FURNISHED, SUPPLY | | | DETAILS ON THE WATER AND SEWER CONNECTIONS TO THESE | | | BUILDINGS. THE WATER CONNECTION SHALL BE PROVIDED W/ A | | | BACKFLOW PREVENTER. |
|