| 2014-08-26 07:18:10 | BUILDING PLAN REVIEW |
| | PERMIT: 14080552 |
| | ADD: 222 LAKEVIEW AVE 1ST FL COMMON AREA |
| | CONT: HOLT LEE |
| | TEL: (954)270-1894 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. AUG. 26/2014 |
| | ACTION: DENIED |
| | |
| | 1) SHEET P1 PLUMBING DEMO DETAIL INDICATES THE REMOVAL |
| | OF A BACK FLOW PREVENTOR. BACK FLOW PREVENTORS ARE |
| | INSTALLED TO PROTECT POTABLE WATER, 2010 FBC-PLUMBING |
| | 608.3 DEVICES, APPURTENANCES, APPLIANCES AND APPARATUS. |
| | ALL DEVICES, APPURTENANCES, APPLIANCES AND APPARATUS |
| | INTENDED TO SERVE SOME SPECIAL FUNCTION, SUCH AS |
| | STERILIZATION, DISTILLATION, PROCESSING, COOLING, OR |
| | STORAGE OF ICE OR FOODS, AND THAT CONNECT TO THE WATER |
| | SUPPLY SYSTEM, SHALL BE PROVIDED WITH PROTECTION |
| | AGAINST BACKFLOW AND CONTAMINATION OF THE WATER SUPPLY |
| | SYSTEM. WATER PUMPS, FILTERS, SOFTENERS, TANKS, |
| | COMMERCIAL DRINKING WATER DISPENSERS AND ALL OTHER |
| | APPLIANCES AND DEVICES THAT HANDLE OR TREAT POTABLE |
| | WATER SHALL BE PROTECTED AGAINST CONTAMINATION. |
| | |
| | PLEASE PROVIDE ADDITIONAL INFORMATION WHY YOU BELIEVE |
| | THIS BACK FLOW PREVENTOR CAN BE REMOVED AND THE |
| | LOCATION JUST MOVED? |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |