| Date |
Text |
| 2014-09-25 09:47:12 | DATE: 9/25/2014 |
| | PROJECT: KITCHEN AND BATH REMODEL |
| | PERMIT#: 14080339 |
| | CODE: 2008 EDITION OF THE NEC |
| | 2010 EDITION OF THE FBC |
| | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, |
| | ADMINISTRATION, 2012 FBC SUPPLEMENTS. |
| | |
| | 1ST ELECTRICAL PLAN REVIEW |
| | ACTION: PROVISO |
| | |
| | 1) LIGHTING OUTLETS SHALL BE INSTALLED WHERE SPECIFIED |
| | IN NEC 210.70(A)1,2,3 |
| | (1) HABITABLE ROOMS. AT LEAST ONE WALL |
| | SWITCH?CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN |
| | EVERY HABITABLE ROOM AND BATHROOM. |
| | (2) ADDITIONAL LOCATIONS. ADDITIONAL LIGHTING OUTLETS |
| | SHALL BE INSTALLED IN ACCORDANCE WITH (A)(2)(A), |
| | (A)(2)(B), AND (A)(2)(C). |
| | (3) STORAGE OR EQUIPMENT SPACES. FOR ATTICS, UNDERFLOOR |
| | SPACES, UTILITY ROOMS, AND BASEMENTS, AT LEAST ONE |
| | LIGHTING OUTLET CONTAINING A SWITCH OR CONTROLLED BY A |
| | WALL SWITCH SHALL BE INSTALLED WHERE THESE SPACES ARE |
| | USED FOR STORAGE OR CONTAIN EQUIPMENT REQUIRING |
| | SERVICING. |
| | |
| | 2) FOR A ONE FAMILY DWELLING AND EACH UNIT OF A |
| | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST |
| | ONE RECEPTACLE OUTLET ACCESSIBLE WHILE STANDING AT |
| | GRADE LEVEL AND LOCATED NOT MORE THAN 2.0 M (61.2 FT) |
| | ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF |
| | THE DWELLING. NEC 210.52(E)(3) |
| | |
| | 3) METAL FRAMING MEMBERS SHALL BE BONDED TO THE |
| | EQUIPMENT GROUNDING CONDUCTOR FOR THE CIRCUIT THAT MAY |
| | ENERGIZE THE FRAMING AND BE SIZED IN ACCORDANCE WITH |
| | THE NEC TABLE 250.122. FOR THE PURPOSE OF THIS SECTION, |
| | A GROUNDED METAL OUTLET BOX ATTACHED TO THE FRAMING |
| | SHALL BE PERMITTED. |
| | |
| | 4) ALL 125V SINGLE PHASE, 15 AND 20AMP RECEPTACLES |
| | INSTALLED IN THE LOCATIONS SPECIFIED IN (1) THROUGH (8) |
| | SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION |
| | FOR PERSONNEL. ALL OUTLETS IN THE GARAGE SHALL BE GFCI |
| | PROTECTED. NEC 210.8. |
| | |
| | 5) FOR A ONE FAMILY DWELLING AND EACH UNIT OF A |
| | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST |
| | ONE RECEPTACLE OUTLET ACCESSIBLE WHILE STANDING AT |
| | GRADE LEVEL AND LOCATED NOT MORE THAN 2.0 M (61.2 FT) |
| | ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF |
| | THE DWELLING. NEC 210.52(E)(3) |
| | |
| | 6) OCCUPIABLE BALCONIES AND PORCHES OVER 20 SQ FT MUST |
| | NOW HAVE A RECEPTACLE OUTLET (GFCI PROTECTED) |
| | (210.52(E)(3). |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. SEE LINK: |
| | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ |
| | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| | |
| | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO |
| | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED |
| | SHEETS FOR COMPARATIVE REVIEW. |
| | |
| | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, |
| | 561-805-6717 OR [email protected] |
| | |