| Plan Review Notes For Permit 14080333 |
| Permit Number |
14080333 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2014-09-13 09:47:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | 1. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL FOR THE | | | ROOF, FAC9N-3. | | | | | | 2ND REVIEW: | | | | | | EVALUATION REPORT FOR ELITE FOAM PANEL ROOF WAS | | | SUBMITTED. | | | | | | INSTALLATION INSTRUCTIONS FOR A PANEL SKYLIGHT WAS | | | SUBMITTED. | | | | | | IT IS NOT CLEAR WHICH PRODUCT IS PROPOSED, OR WHETHER | | | BOTH ARE PROPOSED. PLEASE DETERMINE WHICH PRODUCT OR | | | PRODUCTS ARE TO BE INSTALLED. THEN, PROVIDE BOTH THE | | | EVALUATION REPORT AND THE INSTALLATION INSTRUCTIONS. | | | | | | 2. THE SKYLIGHT PANEL APPEARS TO BE LIMITED TO 170MPH, | | | EXPOSURE B. THIS PROJECT IS FOR 160MPH, EXPOSURE C. IF | | | YOU WISH TO USE THE SKYLIGHT PANEL ON THIS JOB, AN | | | ENGINEERING ANALYSIS IS REQUIRED TO DETERMINE THAT IT | | | MEETS THE DESIGN CRITERIA, FBC 2010 RESIDENTIAL 301. | | | | | | MY RECOMMENDATION IS THAT, WHEN PRODUCT APPROVALS ARE | | | REQUIRED, GO DIRECTLY TO THE WEBSITE | | | WWW.FLORIDABUILDING.ORG, PRINT THE COVER SHEET (WHICH | | | SHOWS APPROVAL NUMBER AND STATUS), EVALUATION REPORT, | | | AND INSTALLATION INSTRUCTIONS. THIS WILL GIVE THE MOST | | | CURRENT AND ACCURATE INFORMATION FOR REVIEW. | | | | | | |
|