Plan Review Notes
Plan Review Notes For Permit 14080042
Permit Number 14080042
Review Stop B
Sequence Number 2
Notes
Date Text
2014-09-22 16:51:42BUILDING PLAN REVIEW
 REVISION: 14080042
 PERMIT: 14021040
 ADD: 721 39TH ST.
 CONT: HERMAN EILBERG CONTRACTING
 TEL: (561)961-9971
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. SEPT. 22/ 2014
 ACTION: DENIED
  
 NOTE: THIS REVISION WAS SUBMITTED UNDER 14090653, IT IS
 A RESUB OF A REVISION # 14080042. THERE IS A CREDIT
 THAT CAN BE TAKEN ON THE NEXT CYCLE OF REVIEWS.
  
 1) THE REVISION IS FOR THE REMOVAL OF THE BLOCK WALL
 AND NEW WOOD FRAME EXTERIOR WALLS. THE REVISION STATES
 THERE IS NO INCREASE IN VALUE OF WORK. NOT IN THE SCOPE
 OF THE ORIGINAL PERMI, THIS IS A INCREASE IN THE SCOPE
 OF WORK AND INCREASED VALUE OF THE PROJECT. PLEASE
 PROVIDE THE VALUE IN THE INCREASE OF WORK!!!! 2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF
 PERMIT FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS,
 MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS
 REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID
 AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE
 ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY.
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) THE REVISION IS LACKING THE ELEMENTS REQUIRED FOR
 PLANS REVIEW. THE PLANS DO NOT PROVIDE WHAT THE ROOM IS
 TO BE USED FOR, IF SLEEPING ROOM THEN IT MUST SHOW
 COMPLIANCE WITH 2010 FBC-R 310.1.1.
 R310.1.1 MINIMUM OPENING AREA.
 ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A
 MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET (0.530
 M2).
 EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM
 NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M2).
  
 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.3.5
 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE
 EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL
 SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND
 DOCUMENTS: A FLOOR PLAN;
 107.3.5.3 RESIDENTIAL (ONE AND TWO-FAMILY)
 REQUIREMENTS SHALL INCLUDE:
 WALL SECTION FROM FOUNDATION THROUGH ROOF, INCLUDING
 ASSEMBLY AND MATERIALS CONNECTOR
 BUILDING ENVELOPE WALL & OPENING PROTECTION WINDOWS
 INTERIOR FINISHES WALL & CEILING
 ROOFING ASSEMBLIES ROOFING IS A SEPARATE PERMIT.
  
 4) R612.5 PERFORMANCE.
 EXTERIOR WINDOWS AND DOORS SHALL BE DESIGNED TO RESIST
 THE DESIGN WIND LOADS SPECIFIED IN TABLE R301.2(2)
 ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLE R301.2(3).
 FOR TESTING REQUIRED IN SECTIONS R612.6, R612.7, AND
 R612.8, DESIGN PRESSURES DETERMINED FROM TABLE
 R301.2(2) OR ASCE 7 ARE PERMITTED TO BE MULTIPLIED BY
 0.6.
  
 R612.6 TESTING AND LABELING.
 EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN
 APPROVED INDEPENDENT TESTING LABORATORY, AND SHALL BE
 LABELED TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF
 ONE OF THE FOLLOWING SPECIFICATIONS:
  
 ANSI/AAMA/NWWDA101/I.S.2 OR ANSI/AAMA/WDMA
 101/I.S.2/NAFS OR AAMA/WDMA/CSA 101/I.S.2/A440 OR TAS
 202 (HVHZ SHALL COMPLY WITH TAS 202 UTILIZING ASTM E
 1300-98 OR ASTM E 1300-04 02).
  
 EXTERIOR WINDOWS AND SLIDING GLASS DOORS SHALL BE
 LABELED WITH A PERMANENT LABEL, MARKING, OR ETCHING
 PROVIDING TRACEABILITY TO THE MANUFACTURER AND PRODUCT.
 THE FOLLOWING SHALL ALSO BE REQUIRED EITHER ON A
 PERMANENT LABEL OR ON A TEMPORARY SUPPLEMENTAL LABEL
 APPLIED BY THE MANUFACTURER: INFORMATION IDENTIFYING
 THE MANUFACTURER, THE PRODUCT MODEL/SERIES NUMBER,
 POSITIVE AND NEGATIVE DESIGN PRESSURE RATING, PRODUCT
 MAXIMUM SIZE, GLAZING THICKNESS, IMPACT RESISTANCE.
 APPROVAL NUMBER, APPLICABLE TEST STANDARD(S), AND
 APPROVED PRODUCT CERTIFICATION AGENCY, TESTING
 LABORATORY, EVALUATION ENTITY OR MIAMI-DADE PRODUCT
 APPROVAL.THE LABELS ARE LIMITED TO ONE DESIGN PRESSURE
 RATING PER REFERENCE STANDARD. THE TEMPORARY
 SUPPLEMENTAL LABEL SHALL REMAIN ON THE WINDOW OR DOOR
 UNTIL FINAL APPROVAL BY THE BUILDING OFFICIAL.
  
 5) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(B) WINDOWS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 6) A ROOFING CONTRACTOR WILL BE REQUIRED FOR THE
 ROOFING PERMIT SINCE THIS IS FLAT WORK FL STATUE 489.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  