| 2014-09-11 13:13:38 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| | COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN |
| | PROFESSIONALS FEES AS REQUIRED BY DCA RULE 9N-3. |
| | VALUATION WAS UPDATED TO $319,326. THE CORRESPONDING |
| | PERMIT FEE BALANCE IS $1639.78. |
| | |
| | 2- DETAIL 1/S-1: SPECIFY HOW HOW MUCH EMBEDMENT IS |
| | REQUIRED FOR THE 3/4" ANCHOR BOLTS. SEC. R301.1 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 3- DETAIL 2/S-2: THIS STEEL COLUMN CONNECTION IS TO |
| | RECEIVE TWO GIRDER TRUSSES. REVISE DETAIL AS REQUIRED. |
| | SEC. R301.1 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 4- WINDOWS AND DOORS WITH GLAZING: PROVIDE |
| | MANUFACTURER'S SPECIFICATIONS SHOWING THE U-FACTOR AND |
| | SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS IN |
| | ITEM #7. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | |
| | 5- ENERGY CALCULATIONS: REVISE THE DOOR TYPE ON PAGE 3 |
| | OF 6. THERE ARE NOT INSULATED DOORS. SEE PLANS AND |
| | PRODUCT APPROVALS SUBMITTED. DOORS WITH GLAZING NEED TO |
| | BE CONSIDERED AS GLAZING. SEE SEC. 405.5.3 OF 2010 |
| | FBC-ENERGY CONSERVATION. |
| | |
| | 6-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | |
| | A) TYPE OF "STICKY BACK" ROOF UNDERLAYMENT AS SPECIFIED |
| | ON PLANS. |
| | |
| | B) ROOF TILE ADHESIVE. NOA 12-0228.18 SUBMITTED WAS |
| | SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA. |
| | |
| | C) 6'-0" WIDE OVERHEAD GARAGE DOOR AS SPECIFIED ON |
| | PLANS. |
| | |
| | D) FIXED WINDOWS. PROVIDE COMPLETE INFORMATION FOR NOA |
| | 03-0502.03 SUBMITTED. INFORMATION SUBMITTED IS THE |
| | COVER PAGE ONLY (9 COPIES SUBMITTED). |
| | |
| | E) SLIDING GLASS DOORS. NOA 11-1018.14 SUBMITTED WAS |
| | SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA. |
| | |
| | 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 |
| | CITY AMENDMENTS TO FBC. |
| | |
| | 8- PROVIDE COPY OF THE IMPACT FEES PAID RECEIPT. COUNTY |
| | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| | CODE. |
| | |
| | ***NOTES: |
| | **PLEASE REMOVE AND REPLACE ANY REVISED SHEET. AND, |
| | PLEASE DON'T STAPLE PRODUCT APPROVALS TO PLANS. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |