| Date |
Text |
| 2014-10-29 16:52:32 | BUILDING PLAN REVIEW |
| | PERMIT: 14071125 |
| | ADD: |
| | CONT: |
| | TEL: (561 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. NOV. 03/2014 |
| | ACTION: DENIED |
| | |
| | |
| | 1) THE SUBMITTED PERMIT APPLICATION IS FOR THE INTERIOR |
| | DEMOLITION AND VALUE REFLECTED IS FOR A INTERIOR DEMO |
| | ONLY. THE NEW SUBMITTED PLANS SHOW THE NEW INTERIOR |
| | BUILD OUT AND CEILING PLANS, NOT A INTERIROR DEMO, |
| | WITHIN THE TITALBLOCK THE PLANS STATE INTERIOR |
| | DEMOLITION AND REMODAL. THE ORIGINAL PLANS THE REMODAL |
| | WAS BLACKED OUT. |
| | |
| | THE NEW INTERIOR BUILD OUT PLANS INDICATE A A2 ASSEMBLY |
| | OCCUPANCY, A RESTARUANT WITH AN OCCUPANT LOAD IN THE |
| | DINING AREA WITH ONLY ONE EXIT THE (2) ENTRY/ EXIT |
| | DOORS ARE NOT 1/2 THE DIAGONAL DISTANCE APART TO BE |
| | CONSIDERED 2 SEPARATE EXITS. |
| | SEE 2010 FBC-B TABLE 1015.1 SPACES WITH ONE EXIT OR |
| | EXIT ACCESS DOORWAY. |
| | |
| | 1014.2 EGRESS THROUGH INTERVENING SPACES. EGRESS |
| | THROUGH INTERVENING SPACES SHALL COMPLY WITH THIS |
| | SECTION. |
| | ( 4.) EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE |
| | ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. |
| | |
| | 1015.2.1 TWO EXITS OR EXIT ACCESS DOORWAYS. |
| | WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED |
| | FROM ANY PORTION OF THE EXIT ACCESS, THE EXIT DOORS OR |
| | EXIT ACCESS DOORWAYS SHALL BE PLACED A DISTANCE APART |
| | EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH OF THE |
| | MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR |
| | AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN |
| | EXIT DOORS OR EXIT ACCESS DOORWAYS. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |