| Plan Review Notes For Permit 14071026 |
| Permit Number |
14071026 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-08-07 08:07:02 | PLUMBING PLAN REVIEW | | | REVISION: 14071026 | | | PERMIT: 14020986 | | | ADD: 777 S FLAGLER DR / 9TH -11 TH FLOOR | | | CONT: CITY CONSTRUCTION | | | TEL: (561)251-3865 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. AUGUST 18/ 2014 | | | ACTION: PLUMBING PROVISO | | | | | | 1) ALL THREE FLOORS 9-11 FLOORS WILL NEED TO PROVIDE | | | COMPLIANCE WITH THE 2010 FBC- ACCESSIBILITY CODE 211.2 | | | MINIMUM NUMBER OF DRINKING FOUNTAINS. NO FEWER THAN (2) | | | DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING | | | FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE | | | DRINKING FOUNTAIN SHALL COMPLY WITH 602.7. | | | | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|