| Plan Review Notes For Permit 14070420 |
| Permit Number |
14070420 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-07-21 11:07:24 | DATE: 7/21/2014 | | | PROJECT: GREEN TERRACE I-56 | | | PERMIT#: 14070420 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) OUTLET BOXES OR OUTLET BOX SYSTEMS USED AS THE SOLE | | | SUPPORT OF A CEILING-SUSPENDED (PADDLE) FAN SHALL BE | | | LISTED, SHALL BE MARKED BY THEIR MANUFACTURER AS | | | SUITABLE FOR THIS PURPOSE, AND SHALL NOT SUPPORT | | | CEILING-SUSPENDED (PADDLE) FANS THAT WEIGH MORE THAN 32 | | | KG (70 LB). FOR OUTLET BOXES OR OUTLET BOX SYSTEMS | | | DESIGNED TO SUPPORT CEILING-SUSPENDED (PADDLE) FANS | | | THAT WEIGH MORE THAN 16 KG (35 LB), THE REQUIRED | | | MARKING SHALL INCLUDE THE MAXIMUM WEIGHT TO BE | | | SUPPORTED. NEC 314.27(D) BOXES AT CEILING-SUSPENDED | | | (PADDLE) FAN OUTLETS. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|