| 2014-07-01 08:54:18 | DATE: 7/1/2014 |
| | PROJECT: RESIDENTIAL DEMOLITION |
| | PERMIT#: 1406 1350 |
| | CODE: 2008 EDITION OF THE NEC |
| | 2010 EDITION OF THE FBC |
| | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, |
| | ADMINISTRATION, 2012 FBC SUPPLEMENTS. |
| | |
| | 1ST ELECTRICAL PLAN REVIEW |
| | ACTION: DENIED |
| | |
| | 1) A CERTIFIED GENERAL CONTRACTOR HAS SUBMITTED FOR A |
| | DEMOLITION AND REPAIR PERMIT THAT INCLUDES DEMOLITION |
| | AND REPAIR OF THE EXISTING ELECTRICAL CIRCUITRY. |
| | |
| | THEREFORE AN ELECTRICAL PERMIT APPLICATION ACCOMPANIED |
| | BY AN ELECTRICAL DEMOLITION AND REPAIR PLAN INDICATING |
| | THE FOLLOWING: |
| | A. A WRITTEN SCOPE OF WORK INDICATING THE EXTENT OF THE |
| | ELECTRICAL DEMOLITION INCLUDING HOW AND WHERE THE |
| | ELECTRICAL CIRCUITRY AFFECTED BY DEMOLITION WILL BE |
| | TERMIATED IN A SAFE AND CODE COMPLIANT MANNER. |
| | B. THE LOCATION OF THE ELECTRICAL SERVICE. |
| | C. THE LOCATION OF THE ELECTRICAL PANEL. |
| | |
| | ACCORDING TO FLORIDA STATE STATUTE, A GENERAL |
| | CONTRACTOR SHALL SUBCONTRACT ALL ELECTRICAL, |
| | MECHANICAL, PLUMBING, ROOFING, SHEET METAL, SWIMMING |
| | POOL, AND AIR-CONDITIONING WORK, UNLESS SUCH CONTRACTOR |
| | HOLDS A STATE CERTIFICATE OR REGISTRATION IN THE |
| | RESPECTIVE TRADE CATEGORY. FLORIDA STATUTE 489.113(3) |
| | |
| | 2) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A |
| | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE |
| | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL |
| | 314.3.1 |
| | |
| | 3) IN GROUP R-2, R-3, AND R-4 OCCUPANCIES AND BUILDINGS |
| | REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL , |
| | THE REQUIREMENTS OF SECTIONS 708.3.1 THROUGH 708.3.7 |
| | SHALL BE APPLICABLE TO WORK AREAS LOCATED WITHIN A |
| | DWELLING UNIT. FBC-EXISTING 708.3 |
| | |
| | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, |
| | 561-805-6717 OR AT [email protected] |