2014-07-07 11:30:361ST REVIEW:
  
 606.4 REPLACEMENT OF WINDOWS AND DOORS.
 THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS,
 SKYLIGHT, OPERATIVE AND INOPERATIVE WINDOWS SHALL BE
 DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16 OF
 THE FLORIDA BUILDING CODE, BUILDING.
 EXCEPTIONS:
 1. OPENING PROTECTION EXCEPTION: FOR ONE- AND
 TWO-FAMILY DWELLINGS CONSTRUCTED UNDER CODES OTHER THAN
 THE FLORIDA BUILDING CODE AND LOCATED IN WINDBORNE
 DEBRIS REGIONS, THE REPLACEMENT OF GARAGE DOORS AND
 EXTERIOR DOORS WITH GLAZING, SLIDING GLASS DOORS, GLASS
 PATIO DOORS, SKYLIGHTS, AND OPERABLE AND INOPERABLE
 WINDOWS WITHIN ANY 12-MONTH PERIOD SHALL NOT BE
 REQUIRED TO HAVE OPENING PROTECTION BUT SHALL BE
 DESIGNED FOR WIND PRESSURES FOR ENCLOSED BUILDINGS,
 PROVIDED THE AGGREGATE AREA OF THE GLAZING IN THE
 REPLACED COMPONENTS DOES NOT EXCEED 25 PERCENT OF THE
 AGGREGATE AREA OF THE GLAZED OPENINGS IN THE DWELLING
 OR DWELLING UNIT.
  
 IMPACT PROTECTION IS REQUIRED IN WIND BOURNE DEBRI
 REGIONS:
  