Plan Review Notes
Plan Review Notes For Permit 14060915
Permit Number 14060915
Review Stop B
Sequence Number 1
Notes
Date Text
2014-07-10 16:08:472010 FBC
  
 DENIED BY BUILDING
  
 1) THIS STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE. THE
 ELEVATION CERTIFICATE THAT WAS SUBMITTED INDICATES THAT
 THE STRUCTURE AND GARAGE ARE BOTH ABOVE THE REQUIRED
 MINIMUM OF 7.5 FEET NGVD. HOWEVER, IT ALSO SHOWS THAT
 SOME OF THE EQUIPMENT THAT SERVICES THE BUILDING IS TOO
 LOW. THIS WILL NEED TO BE CORRECTED AND A NEW ELEVATION
 CERTIFICATE SHOWING COMPLIANCE IS REQUIRED PRIOR TO
 RECIEVING FINAL INSPECTION APPROVAL. CITY OF WEST PALM
 BEACH FLOOD ORDINANCE.
  
 2) THE PLANS SHOW A DUAL FUEL GRIDDLE AND RANGE. PLEASE
 CALARIFY THE TYPE OF FUEL THAT THIS APPLIANCE WILL USE.
 IF IT USES NATURAL OR LP GAS A SEPARATE PERMIT,
 APPLICATION AND REVIEW OF THE GAS RISER PLAN WILL BE
 REQUIRED.
  
 3) SHOW COMPLIANCE WITH FBCR 315 FOR CARBON MONOXIDE
 ALARMS.
  
 4) FBCR 803.2.3.1 REQUIRES THE ROOF SHEATHING TO BE
 FASTENED WITH 8D RING SHANK NAILS. PLEASE CORRECT NOTES
 ON SHEET A4.
  
 5) SUBMIT TWO SETS OF ENERGY COMPLIANCE DOCUMENTS AS
 REQUIRED BY FBC ENERGY CONSERVATION SECTION 103.2
  
 6) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE ROOFING
 MATERIAL AS REQUIRED BY DCA RULE 9N-3.
  
 7) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY
 AMENDMENTS 107.3.4.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]