Plan Review Notes
Plan Review Notes For Permit 14060747
Permit Number 14060747
Review Stop B
Sequence Number 1
Notes
Date Text
2014-07-08 08:47:24****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. AS DISCUSSED, PLEASE PROVIDE AN ORIGINAL ELEVATION
 CERTIFICATE. THE SURVEYOR HAS AGREED TO PROVIDE THIS
 DIRECTLY TO ME. CITY OF WEST PALM BEACH MUNICIPAL CODE
 94-546(B)
  
 2. FBC 2010 ACCESSIBILITY 202.1, 224.2, 402, 806.2.2,
 PROVIDE INFORMATION REGARDING ACCESSIBLE ROOMS. IT IS
 NOT CLEAR WHETHER THESE ROOMS ARE AFFECTED BY THE
 PROPOSED RENOVATION.
  
 INDICATE WHICH OPTION ARE PROPOSED, INCLUDING SILL
 HEIGHT, SEE SHEETS 7-9.
  
 3. THE PRODUCT APPROVALS WERE PRINTED IN "PORTRAIT"
 ORIENTATION. PLEASE REPRINT THE DRAWING SHEETS IN
 "LANDSCAPE" SO THEY PRINT FULL SIZE. THE SHEETS
 SUBMITTED ARE TOO SMALL TO READ, REVIEW, INSPECT FROM,
 AND SCAN, FBC 107.
  
 4. PROVIDE A PLAN SHOWING LOCATION OF PROPOSED DOOR
 INSTALLATION. APPLICATION DESCRIPTION STATES THAT YOU
 PROPOSE TO "REPLACE EXISTING CORRIDOR AND STAIRWAY
 WINDOWS WITH NEW IMPACT WINDOWS." CORRIDORS AS DEFINED
 IN FBC 1002 ARE RATED. SOME STAIRS ARE REQUIRED TO BE
 RATED. NOT ENOUGH INFORMATION HAS BEEN PROVIDED TO
 DETERMINE CODE COMPLIANCE.
  
 5. STOREFRONT DOOR PRODUCT APPROVALS SUBMITTED. PROVIDE
 A PLAN SHOWING PROPOSED LOCATION. INDICATE HARDWARE
 PROPOSED (PANIC/FIRE EXIT HARDWARE, SILL), FBC
 1008.1.10, FBC 2010 ACCESSIBILITY 402. NOT ENOUGH
 INFORMATION PROVIDED TO DETERMINE CODE COMPLIANCE.
  
 SEE SHEET 3 OF STOREFRONT DOOR NOA. THERE ARE TWO
 OPTIONS FOR THRESHOLD COVER; THE ADA COVER IS LIKELY
 REQUIRED.
  
 IF FIRE EXIT HARDWARE AND ADA THRESHOLD SILL ARE
 PROPOSED, A LIFE SAFETY PLAN IS NOT REQUIRED. IF
 PROPOSED INSTALLATION DOES NOT INCLUDE FIRE EXIT
 HARDWARE AND/OR ADA THRESHOLD, A LIFE SAFETY PLAN WILL
 BE REQUIRED TO DEMONSTRATE THAT THEY ARE NOT REQUIRED.
  
 6. THIS PROPERTY HAS SEVERAL EXPIRED PERMITS. PLEASE
 HAVE THE OWNER RESOLVE.
  
 THE OWNER CAN SEE THE EXPIRED PERMITS AT THE FOLLOWING
 WEBSITE:
  
 HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT
 US.ASPX
  
 ENTER THE ADDRESS ONLY (600 NORTHPOINT). FOR PERMITS
 FOR WHICH THE WORK WAS NEVER STARTED, FAX A NOTARIZED
 LETTER STATING THIS TO 561-805-6676 (INCLUDE ADDRESS,
 PERMIT NUMBER, AND SCOPE OF PERMIT).
  
 FOR PERMITS WHICH WERE ISSUED, OBTAINED ALL REQUIRED
 INSPECTIONS EXCEPT FOR A FINAL INSPECTION, AN
 "INSPECTION ONLY" PERMIT CAN BE APPLIED FOR TO OBTAIN A
 PERMIT TO CLOSE THE EXPIRED PERMIT.
  
 FOR PERMITS WHICH WERE ISSUED AND NEED MORE INSPECTIONS
 THAN THE FINAL ONLY, A CONTRACTOR IS TO APPLY FOR A
 "REISSUE" PERMIT.
  
 FOR PERMITS WHICH WERE NEVER ISSUED BUT THE WORK WAS
 STARTED WITHOUT PERMIT, A CONTRACTOR IS TO APPLY FOR A
 NEW PERMIT.
  
  
  
  