2014-06-12 13:26:27BUILDING PLAN REVIEW
 PERMIT: 14060385
 ADD: 718 40 TH ST
 CONT: O/B TRIPP ODELL
 TEL: (561)206-7340
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JUNE 12/ 2014
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION INDICATES UNDER THE
 DESCRIPTION OF WORK TO REROOF PAPER & SHINGLES.
 SUBMITTED IS PAPERWORK (1 SET OF PRODUCT APPROVALS)
 FOR A FLAT DECK, NOT IN THE DESCRIPTION OF WORK. NO
 PRODUCT APPROVALS WERE SUBMITTED FOR SHINGLES NOR WAS
 THE PITCH OF THE ROOF PROVIDED.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.1 GENERAL.
 SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION
 DOCUMENTS, STATEMENT OF SPECIAL INSPECTIONS,
 GEOTECHNICAL REPORT AND OTHER DATA SHALL BE SUBMITTED
 IN TWO OR MORE SETS WITH EACH
 PERMIT APPLICATION.
  
 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE
 CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND
 DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND
 RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED.
 PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE
 COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE.
  
 2010 FBC-R R905.2.7 UNDERLAYMENT APPLICATION. FOR ROOF
 SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL
 (17-PERCENT SLOPE), UP TO FOUR UNITS VERTICAL IN 12
 UNITS HORIZONTAL (33-PERCENT SLOPE), TWO LAYERS OF
 UNDERLAYMENT COMPLYING WITH ASTM D 226 TYPE I OR TYPE
 II, ASTM D 4869 TYPE I OR TYPE II, OR ASTM D 6757 SHALL
 BE APPLIED IN THE FOLLOWING MANNER:
 1. APPLY A MINIMUM 19-INCH-WIDE (483 MM) STRIP OF
 UNDERLAYMENT FELT PARALLEL WITH AND STARTING AT THE
 EAVES.
  
 2. STARTING AT THE EAVE, APPLY 36-INCH-WIDE (914 MM)
 SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19
 INCHES (483 MM). DISTORTIONS IN THE UNDERLAYMENT SHALL
 NOT INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL.
 3. END LAPS SHALL BE OFFSET BY 6 FEET (1829 MM).
 4. CORROSION RESISTANT FASTENERS ARE TO BE APPLIED
 ALONG THE OVERLAP AT A MAXIMUM SPACING OF 36 INCHES
 (914 MM) ON CENTER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  