| Date |
Text |
| 2014-07-05 09:16:18 | BUILDING PLAN REVIEW |
| | PERMIT: 14060348 |
| | ADD: 1301 BELVEDERE RD |
| | CONT: TBD |
| | TEL: (267)251-8336 |
| | |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: WED. JULY 05/2014 |
| | |
| | ACTION: BUILDING PROVISO |
| | BUILDING APPROVED WITH EXCEPTION! |
| | |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | |
| | 1) 2010 FLORIDA ACCESSIBILITY CODE 202.4.2 ACCESSIBLE |
| | FEATURES IN THE EVENT OF DISPROPORTIONALITY. |
| | WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| | OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| | DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| | ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| | ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| | FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| | ALARMS. |
| | |
| | SHEET A110 INDICATES WORK ON THE CURB. PLEASE PROVIDE |
| | COMPLIANCE WITH 2010 FLORIDA ACCESSIBILITY CODE, 503.1 |
| | GENERAL. |
| | PASSENGER LOADING ZONES SHALL COMPLY WITH 503. |
| | |
| | 503.2 VEHICLE PULL-UP SPACE. |
| | PASSENGER LOADING ZONES SHALL PROVIDE A VEHICULAR |
| | PULL-UP SPACE 96 INCHES (2440 MM) WIDE MINIMUM AND 20 |
| | FEET (6100 MM) LONG MINIMUM. |
| | |
| | 503.3 ACCESS AISLE. |
| | PASSENGER LOADING ZONES SHALL PROVIDE ACCESS AISLES |
| | COMPLYING WITH 503 ADJACENT TO THE VEHICLE PULL-UP |
| | SPACE. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE |
| | AND SHALL NOT OVERLAP THE VEHICULAR WAY. |
| | |
| | FIGURE 503.3 |
| | PASSENGER LOADING ZONE ACCESS AISLE |
| | |
| | 503.3.1 WIDTH. |
| | ACCESS AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE |
| | 60 INCHES (1525 MM) WIDE MINIMUM. |
| | |
| | 503.3.2 LENGTH. |
| | ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE |
| | VEHICLE PULL-UP SPACES THEY SERVE. |
| | |
| | 503.3.3 MARKING. |
| | ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE |
| | PARKING IN THEM. |
| | |
| | 503.4 FLOOR AND GROUND SURFACES. |
| | VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM |
| | SHALL COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE |
| | SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. |
| | CHANGES IN LEVEL ARE NOT PERMITTED. |
| | |
| | 2) DEFERRED SUBMITTAL; ROOFING PRODUCT APPROVAL. SHEET |
| | A510 DETAIL # 5 INDICATES THE USE OF FLUID APPLIED |
| | FLEXIBLE ACRYLIC ROOFING, & SHEET A515 DETAIL # 14 |
| | INDICATES THE USE OF TPO ROOFING PRODUCTS. PLEASE |
| | PROVIDE ROOFING PRODUCT APPROVALS FOR EACH OF THESE |
| | SYSTEMS. NOTE IF ZONES 2 & 3 WILL REQUIRE ENHANCED |
| | FASTENING AND IF A MIAMI-DADE NOA LIMITATION 7 OR 9 IS |
| | INDICATED FOR THE SUBSYSTEM. FLORIDA DEPARTMENT OF |
| | COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: (31)(D) ROOFING |
| | PRODUCTS AND ASSEMBLIES. |
| | |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |