| 2014-07-07 12:33:58 | BUILDING PLAN REVIEW |
| | PERMIT: 14060196 |
| | ADD:777 S FLAGLER 12TH FLOOR |
| | CONT: WOOLEMS |
| | TEL: (561)835-0401 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. JULY 07/2014 |
| | ACTION: DENIED |
| | |
| | 1) THE PLANS DO NOT PROVIDE THE ADDRESS WHERE THE WORK |
| | IS TO OCCUR. FL S 61G-16.004(3) LOCATION OF PROJECT. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 2) THE SCOPE OF THIS PROJECT WILL NEED SOME EXPLAINING. |
| | THE PERMIT APPLICATION INDICATES WORK TO BE |
| | ACCOMPLISHED UNDER THIS PERMIT ON THE 12TH & 13TH |
| | FLOORS. WHERE AS PLANS INDICATE 007-A0.07 12-14 FLOORS, |
| | 011-A1.04 DEMO 15TH FLOOR & 015-A1.10 CONSTRUCTION |
| | PLANS FOR THE 15TH LEVEL. IS THIS A PHASED PERMIT OR IS |
| | THE SCOPE OF WORK TO INCLUDE ALL THESE FLOORS? |
| | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 3) SHEET A0.08 LIFE SAFETY PLANS:MISSING PLAN REVIEW |
| | CRITERIA: |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, |
| | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | 107.3.5.1.1 BUILDING |
| | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| | SHALL BE DETERMINED. |
| | MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE |
| | TABLE 503). |
| | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| | OCCUPANCY LOAD |
| | GROSS OR NET TABLE FBC-B 1004.1.1. PER FLOOR |
| | |
| | 4) THE STRUCTURAL WORK ON THIS BUILDING ISCLASSIFYING |
| | IT AS A :THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " |
| | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS |
| | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH |
| | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN |
| | THE |
| | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA |
| | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. |
| | |
| | 4A) 109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A |
| | SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON |
| | A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL |
| | INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE |
| | STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE |
| | ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING |
| | PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING. |
| | THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO |
| | PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO |
| | THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR |
| | COMPLIANCE WITH THE PERMITTED DOCUMENTS. |
| | |
| | 4B) THRESHOLD INSPECTOR: |
| | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES |
| | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL |
| | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA |
| | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS |
| | CODE. A THRESHOLD AGREEMENT WILL NEED TO BE SIGNED BY |
| | ALL PARTIES, PLEASE PROVIDE A E-MAIL ADDRESS THAT WE |
| | CAN SEND ALL THE REQUIRED DOCUMENTS. |
| | |
| | 4C) THRESHOLD BLDG, REQUIRED STATEMENT: |
| | W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING |
| | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE |
| | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT |
| | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S |
| | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE |
| | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE |
| | LOCAL AUTHORITY IN |
| | ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. |
| | |
| | |
| | 4D) CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR |
| | PROGRAM AT (561)805-6666 OR [email protected] FOR FURTHER |
| | INFORMATION: |
| | 4D) (1) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| | HISTORY FOR THIS TYPE OF CONSTRUCTION. |
| | 4D) (2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A |
| | RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. |
| | THE RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| | MEETING THE ABOVE CRITERIA. |
| | CONTACT KEN CONRAD |
| | TEL: 561-805-6666 |
| | E-MAIL: [email protected] |
| | |
| | 4E) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED |
| | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| | INSPECTIONS. |
| | |
| | 4F) A COLLOR COPY OF THE PLANS WILL BE REQUIRED AT THE |
| | JOBSITE FOR CITY INSPECTORS & A SECOND COLOR COPY FOR |
| | THE THRESHOLD INSPECTOR. |
| | |
| | 4G) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES |
| | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER |
| | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE |
| | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR |
| | WALLS AND CEILINGS. |
| | |
| | 5) SHEET 013 A1.09: |
| | 5A) ROOM 1405, THE PRIVATE EXECUTIVE RESTROOM, IT |
| | APPEARS THERE ARE CURVED WALLS WITH A POCKET DOOR, IT |
| | APPEARS THE POCKET IS OUTSIDE OF THE WALL. 107.2,1,3 |
| | ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 5B) PRIVATE ELEVATOR SWING DOOR 1406 ANY DOOR IN A |
| | MEANS OF EGRESS SHALL LEAVE UNOBSTRUCTED AT LEAST ONE |
| | HALF OF THE REQUIRED WIDTH OF THE PASSAGEWAY. 2010 |
| | FBC-B 1008.1.9.11. |
| | |
| | 5C) EXTERIOR BALCONY 1450A NOTE FOR NEW BALCONIES SHALL |
| | BE AMERICAN HYDROTECH CONCRETE PAVER SYSTEM NOA |
| | 08-0422.12 NOTE THIS IS NOT A PAVER SYSTEM BUT A |
| | WATERPROOFING SYSTEM. THIS IS A EXPIRED NOA . PLEASE |
| | PROVIDE A CURRENT APPROVAL AND TYPE OF DECKING SYSSTEM |
| | THAT WILL BE APPLIED ON TOP OF THE WATERPROOFING |
| | SYSTEM. |
| | |
| | 5D) SHOWER ROOMS 1432 (MENS) & 1433 (LADIES) BOTH SHOW |
| | SHOWERS BUT THE PLANS DO NOT INDICATE SIZE OF THE |
| | SHOWER NOR A SEAT DETAIL AS REQUIRED BY 2010 FL ACC |
| | CODE 608.2.1. |
| | |
| | 5E) THE PLANS INDICATE A EXTERIOR DINING AREA (1426) |
| | PLEASE PROVIDE COMPLIANCE WITH THE 2010 FL |
| | ACCESSIBILITY CODE 404.2.5 THRESHOLDS. |
| | |
| | 5F) THE NEW MONUMENTAL STAIRS WILL NEED TO PROVIDE |
| | DETAILS THAT WILL SHOW COMPLIANCE WITH THE 2010 FBC-B |
| | 708.2 EXCEPTION 2.1 WHERE THE AREA OF THE FLOOR OPENING |
| | BETWEEN STORIES DOES NOT EXCEED TWICE THE HORIZONTAL |
| | PROJECTED AREA OF THE ESCALATOR OR STAIRWAY AND THE |
| | OPENING IS PROTECTED BY A DRAFT CURTAIN AND CLOSELY |
| | SPACED SPRINKLERS IN ACCORDANCE WITH NFPA 13. IN OTHER |
| | THAN GROUPS B AND M, THIS APPLICATION IS LIMITED TO |
| | OPENINGS THAT DO NOT CONNECT MORE THAN FOUR STORIES. |
| | |
| | 6) SHEET 015 A1.10 LEVEL 15: |
| | |
| | 6A) DOOR # 1502 APPEARS TO HAVE ONLY 16 1/2 INCHES ON |
| | THE LATCH SIDE OF THE DOOR, SEE 2010 FL ACC CODE FIGURE |
| | 404.2.4.1. (A). |
| | |
| | 6B) THE GYM IS ON THE 15 FLOOR LEVEL AND ONLY 1 MEANS |
| | OF EGRESS. PLEASE SEE 2010 FBC-B TABLE 1021.2. |
| | |
| | 6C) A/C EQUIPMENT HATCH DETAIL # 1 A5.03 PROVIDE THE |
| | MANUFACTURERS SPECIFICATIONS ON THE ACUDOOR FLOOR DOOR |
| | PROVIDE FLOOR LOADING TABLE 1607(LBS) AND FIRE RATING |
| | TABLE 715.4. FOR THE FLOOR DOOR. |
| | |
| | 7) STRUCTURAL SHEEETS SHOW STEEL FRAMING MEMBERS, THIS |
| | IS A TYPE 1A BUILDING SHOW COMPLIANCE WITH TABLE 603 |
| | WITH REQUIRED FIRE RESISTANCE RATING REQUIREMENTS FOR |
| | BUILDING ELEMENTS (HOURS) PROVIDE THICKENESS AND HOUR |
| | RATING. |
| | |
| | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |