| Date |
Text |
| 2014-07-22 09:37:05 | ****CORRECTIONS**** |
| | ****PLAN REVIEW IN PROGRESS**** |
| | ****REVISED 7/23/14**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | ELEVATION CERTIFICATE PREPARED BY PAUL VALENTINE, |
| | EXACTA LAND SURVEYORS, INC. DATED 6/30/2014 |
| | |
| | PERMIT # 14050876, FREDA SANDERSON RESIDENCE |
| | YOUR JOB # FL1406.3907EC |
| | ADDRESS: 3400 N FLAGLER DRIVE |
| | WEST PALM BEACH, FL 33407 |
| | |
| | 1. THE LATITUDE/LONGITUDE APPEAR TO BE THE COORDINATES |
| | FOR 521 46TH STREET. SEE ELEVATION CERTIFICATE |
| | INSTRUCTIONS, ITEM A5. COORDINATES ARE TO BE AT THE |
| | FRONT CENTER OF THE BUILDING AND TO BE ACCURATE WITHIN |
| | 66'. PLEASE CALL ME TO DISCUSS IF YOU BELIEVE THAT THE |
| | COORDINATES PROVIDED ARE CORRECT. |
| | |
| | 2. SEE ELEVATION CERTIFICATE INSTRUCTIONS. WHEN |
| | LAT/LONG DATA IS PROVIDED BY A SURVEYOR, SOURCE OF DATA |
| | IS TO BE INCLUDED IN THE COMMENTS SECTION. |
| | |
| | 3. BUILDING PLANS SHOW THREE SEPARATE BUILDINGS. A |
| | SEPARATE ELEVATION CERTIFICATE IS REQUIRED FOR EACH |
| | BUILDING. SEE ELEVATION CERTIFICATE INSTRUCTIONS ITEM |
| | A1 TO A4. |
| | |
| | 4. ITEM A9A, 360 SF SHOWN AS GARAGE AREA. THE MAIN |
| | HOUSE HAS A 622 SF ATTACHED GARAGE. THERE IS ALSO A |
| | DETACHED GARAGE. DIMENSIONS ARE TO BE TAKEN FROM THE |
| | OUTSIDE OF THE BUILDING. PLEASE REVISE. THE GARAGE FOR |
| | THIS ELEVATION CERTIFICATE SHOULD BE THE ONE ATTACHED |
| | TO THE MAIN HOUSE. |
| | |
| | 5. A SIGNED, SEALED, DATED ORIGINAL ELEVATION |
| | CERTIFICATE IS REQUIRED PER NFIP GUIDELINES. |
| | |
| | 6. A ALL HAS BEEN PLACED TO THE FLORIDA BOARD OF LAND |
| | SURVEYORS FOR AN OPINION ON USING GPS TECHNOLOGY RATHER |
| | THAN DIFFERENTIAL LEVELING TO DETERMINE ELEVATIONS FOR |
| | THE PURPOSE OF COMPLETING AN ELEVATION CERTIFICATE. |
| | |
| | 7/23 - RESPONSE FROM ISO, NO BENCHMARK REQUIRED FOR |
| | PURPOSES OF FEMA/NFIP |
| | |