| 2014-05-25 09:47:25 | BUILDING PLAN REVIEW |
| | PERMIT: 14050851 |
| | ADD: 777 S FLAGLER DR. SUITE # 900 W |
| | CONT: FISHER |
| | TEL: (561)691-4716 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SUNDAY MAY 25 TH/ 2014 |
| | ACTION: DENIED |
| | |
| | NOTE, NO ACTION IS REQUIRED, ROOMS 904 & 912 FALL UNDER |
| | THE COMMON PATH OF TRAVEL BUSINESS OCC. SPRINKLERED |
| | BLDG 100 FEET WITH A OCCUPANT LOAD OF LESS THAN 49 |
| | OCCUPANTS. |
| | |
| | 1) THIS PERMIT IS A PHASED PERMIT, WITH A PHASE I AND |
| | PHASE II. THE PLANS DO NOT INDICATE IF THE PHASE II |
| | PART OF THE PROJECT WILL STATE AFTER PHASE 1 IS |
| | COMPLETE OR WILL THEY |
| | STAT AT THE SAME TIME AND ONLY PHASE 1 LOOK FOR A |
| | TEMPORARY C.O.? THE CONCERN IS THE 2ND PHASE |
| | COMPLETEING BEOFE THE 1ST PHASE, AND IF SO THE 2ND |
| | REQUIRED EXIT THAT WOULD BE IN THE PHASE 1 PORTION OF |
| | THE PERMIT. OCCUPANT LOADS > THAN 49 OCCUPANTS |
| | REQUIRING THE 2 EXITS, 2010 FBC-B 1015.1. |
| | |
| | 2) THIS TENANT SPACE HAS 5 AREAS OF CONFERENCE ROOMS |
| | PLEASE SHOW COMPLIANCE WITH 2010 FBC-B 508.2.1 THAT |
| | THESE AREAS CAN BE CONSIDERED ACCESSORY OCCUPANCIES |
| | UNDER 2010 FBC-B 508.2.1. THE AREA FOR ALL BREAK ROOMS |
| | & CONFERENCE ROOMS HAS TO BE TAKEN INTO ACCOUNT. |
| | 508.2.1 AREA LIMITATIONS. AGGREGATE ACCESSORY |
| | OCCUPANCIES SHALL NOT OCCUPY MORE THAN 10 PERCENT OF |
| | THE BUILDING AREA OF THE STORY IN WHICH THEY ARE |
| | LOCATED AND SHALL NOT EXCEED THE TABULAR VALUES IN |
| | TABLE 503, WITHOUT BUILDING AREA INCREASES IN |
| | ACCORDANCE WITH SECTION 506 FOR SUCH ACCESSORY |
| | OCCUPANCIES. |
| | |
| | BOAF INFORMAL INTERPRETATION REPORT # 6506 |
| | DATE: THU JUN 3 2010 |
| | REPORT: 6506 |
| | CODE: BUILDING CODE YEAR: 2007 |
| | SECTION: 508.3.1 |
| | QUESTION: |
| | IS IT THE INTENT OF FLORIDA BUILDING CODE - BUILDING |
| | SECTION 508.3.1, EXCEPTION 1, TO NOT REQUIRE FIRE |
| | SEPARATION BETWEEN THE |
| | PRIMARY OCCUPANCY AND MULTIPLE ACCESSORY OCCUPANCIES, |
| | WHEN EACH ACCESSORY OCCUPANCY IS LESS THAN 750 SQ. FEET |
| | EACH OR |
| | ONLY WHEN THE TOTAL OF ALL ACCESSORY OCCUPANCIES IS |
| | LESS THAN 750 SQ. FEET IN AREA? |
| | COMMENT: |
| | AN EXAMPLE WOULD BE A BUSINESS OCCUPANCY WITH ONE |
| | ACCESSORY AREA OF 700SF FOR GATHERINGS AND MEETINGS AND |
| | A SECOND |
| | ACCESSORY AREA OF 650SF FOR FITNESS AND WORKOUT. IS THE |
| | EXCEPTION LIMITATION OF 750 S.F. MAX APPLIED TO EACH |
| | ACCESSORY AREA, IN |
| | WHICH CASE THIS BUILDING WOULD COMPLY, OR TO THE |
| | COMBINED TOTAL OF THE TWO ACCESSORY AREAS, IN WHICH |
| | CASE IT WOULD NOT? |
| | ANSWER: |
| | NO. CONSIDERING BOTH SPACES TO BE ASSEMBLY USES LOCATED |
| | ON THE SAME FLOOR, THE EXCEPTION TO FLORIDA BUILDING |
| | CODE - BUILDING |
| | SECTION 508.3.1 WOULD NOT REQUIRE SEPARATION OF EITHER |
| | SPACE. HOWEVER, THE SECTION TO WHICH THE EXCEPTION |
| | RELATES WOULD LIMIT |
| | THE AGGREGATE ACCESSORY OCCUPANCIES TO 10% OF THE AREA |
| | OF THE FLOOR ON WHICH THEY ARE LOCATED. IF THE AREA OF |
| | TWO COMBINED |
| | ASSEMBLY USES EXCEEDED 10%, THEN AT LEAST ONE OF THE |
| | ASSEMBLY USES WOULD REQUIRE FIRE RESISTANT RATED |
| | SEPARATION OF 2 HOURS IN |
| | A NON-SPRINKLED BUILDING AND 1 HOUR IN A BUILDING |
| | SPRINKLED THROUGHOUT. |
| | COMMENTARY: |
| | NONE. |
| | NOTICE: THE BUILDING OFFICIALS ASSOCIATION OF FLORIDA, |
| | IN COOPERATION WITH THE FLORIDA BUILDING COMMISSION, |
| | THE FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ICC, |
| | AND INDUSTRY AND PROFESSIONAL EXPERTS OFFER THIS |
| | INTERPRETATION OF THE FLORIDA BUILDING CODE IN THE |
| | INTEREST OF CONSISTENCY IN THEIR APPLICATION STATEWIDE. |
| | THIS INTERPRETATION IS INFORMAL, NON-BINDING AND |
| | SUBJECT TO ACCEPTANCE AND APPROVAL BY THE LOCAL |
| | BUILDING OFFICIAL. |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |