| Date |
Text |
| 2014-05-29 09:33:55 | ADDITIONAL 1ST REVIEW NOTES: |
| | |
| | RECEIVED EMAIL FROM APPLICANT, THIS IS IN RESPONSE TO |
| | THE FURTHER INFORMATION PROVIDED AND TO CLARIFY |
| | ADDITIONAL REQUIREMENTS. |
| | |
| | 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING |
| | INFORMATION: |
| | |
| | TOTAL NUMBER OF PARKING SPACES |
| | NUMBER OF ACCESSIBLE SPACES |
| | LOCATION OF ACCESSIBLE ENTRANCES |
| | LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES |
| | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY |
| | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE |
| | ENTRANCE |
| | |
| | SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 |
| | (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE |
| | ROUTE). |
| | |
| | YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL, |
| | PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS |
| | RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE |
| | PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR |
| | ACCESSIBLE DESIGN." |
| | |
| | HTTP://WWW.ADA.GOV/RESTRIPE.HTM |
| | |
| | 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE |
| | ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES, |
| | MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE |
| | INDICATE LOCATION ON PLAN. |
| | |
| | 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE |
| | THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107. |
| | |
| | STEVEN KENNEDY |
| | [email protected] |
| | 561 805 6710 |
| 2014-05-27 06:32:35 | 1ST REVIEW: |
| | |
| | |
| | 1) THE SCOPE OF THE INTENDED WORK IS UNCLEAR, THE |
| | VALUATION APPEARS LOW IF THE SCOPE OF WORK IS FOR THE |
| | ENTIRE SITE DEPICTED IN THE PLAN. |
| | |
| | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING |
| | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE |
| | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY |
| | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST |
| | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS |
| | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | |
| | 2) IS THERE ANY INTENT TO ENHANCE ACCESSIBILITY |
| | FEATURES THAT MAY BE NONCONFORMING? |
| | |
| | FBC ACCESSIBILITY-202.4 ALTERATIONS AFFECTING PRIMARY |
| | FUNCTION AREAS. |
| | IN ADDITION TO THE REQUIREMENTS OF 202.3, AN ALTERATION |
| | THAT AFFECTS OR COULD AFFECT THE USABILITY OF OR ACCESS |
| | TO AN AREA CONTAINING A PRIMARY FUNCTION SHALL BE MADE |
| | SO AS TO ENSURE THAT, TO THE MAXIMUM EXTENT FEASIBLE, |
| | THE PATH OF TRAVEL TO THE ALTERED AREA, INCLUDING THE |
| | REST ROOMS, TELEPHONES, AND DRINKING FOUNTAINS SERVING |
| | THE ALTERED AREA, ARE READILY ACCESSIBLE TO AND USABLE |
| | BY INDIVIDUALS WITH DISABILITIES, UNLESS SUCH |
| | ALTERATIONS ARE DISPROPORTIONATE TO THE OVERALL |
| | ALTERATIONS IN TERMS OF COST PURSUANT TO 202.4.1. |
| | ALTERATIONS TO WINDOWS, HARDWARE, CONTROLS, ELECTRICAL |
| | OUTLETS, AND SIGNAGE SHALL NOT BE DEEMED TO BE |
| | ALTERATIONS THAT AFFECT THE USABILITY OF OR ACCESS TO |
| | AN AREA CONTAINING A PRIMARY FUNCTION. |
| | |
| | STEVEN KENNEDY, CBO |
| | CHIEF PLANS EXAMINER |
| | (561) 805-6710 |
| | [email protected] |
| | |
| | |
| | |