Date Text
2014-05-26 18:26:47BUILDING PLAN REVIEW
 PERMIT: 14050677
 ADD: 303 BANYAN 1ST FLOOR COMMON RESTROOMS
 CONT: TBD
 TEL: (904)256-2151
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2010 FL ACCESSIBILITY CODE 604.8 WHEELCHAIR ACCESSIBLE
 TOILET COMPARTMENTS SHALL MEET THE REQUIREMENTS OF
 604.8.1 AND 604.8.3. COMPARTMENTS CONTAINING MORE THAN
 ONE PLUMBING FIXTURE SHALL COMPLY WITH 603
  
 . 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 EXCEPTIONS:
  
 2. WHERE THE TOILET ROOM OR BATHING ROOM IS FOR
 INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH
 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE
 DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE
 CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY
 FIXTURE.