| 2014-06-09 18:59:50 | RESIDENTIAL (R3) ALTERATION/RENOVATION BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- SHEET #1: UNIT #2 SHOWS A PROPOSED BEDROOM WHERE THE | | | GARAGE WAS LOCATED. PROVIDE SPECIFICATIONS SHOWING HOW | | | THE FINISH FLOOR IS GOING TO BE RAISED TO COMPLY WITH | | | SEC. R404.1.6 OF 2010 FBC-RESIDENTIAL. | | | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.4.3 OF 2010 FBC-RESIDENTIAL. | | | | | | 3- TENANT SEPARATION DETAIL: PROVIDE TENANT SEPARATION | | | ASSEMBLY NUMBER (UL LISTING OR GYPSUM BOARD LISTING) | | | USING 2 X 4 WOOD STUDS INSTEAD OF METAL STUDS TO VERIFY | | | COMPLIANCE WITH SEC. R302.3 OF 2010 FBC-RESIDENTIAL. | | | ASSEMBLY NEEDS TO BE TESTED IN ACCORDANCE WITH ASTM E | | | 119 OR UL 263. | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF SHINGLES. | | | | | | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS | | | AND DETAILS. | | | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 |
|