| Plan Review Notes For Permit 14050503 |
| Permit Number |
14050503 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-05-15 17:21:24 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- FLAT ROOF NOA 12-0716.18 SUBMITTED WAS SUPERSEDED BY | | | MIAMI-DADE. NEED TO PROVIDE CURRENT NOA AS REQUIRED BY | | | DCA RULE 9N-3. VISIT THE MIAMI-DADE WEBSITE DOWNLOAD | | | CURRENT NOA AND RESUBMIT 2 COPIES. | | | | | | 2- ARCHITECT TO REVISE THE RAS 117 CALCULATIONS | | | SUBMITTED: | | | | | | A) REVISE THE NOA NUMBER FOR CURRENT NOA. | | | ***NOTE: COORDINATE WITH ITEM #1 ABOVE. | | | | | | B) REVISE THE DESIGN PRESSURES FOR SELECTED ASSEMBLY. | | | PAGE 14 OF NOA 12-0716.18 SUBMITTED DOESN'T HAVE ANY | | | ASSEMBLY WITH THE 52.5 PSF DESIGN PRESSURES. SEE | | | SELECTED ASSEMBLY AND REVISE AS REQUIRED. | | | ***NOTE: COORDINATE WITH ITEM #1 ABOVE. | | | | | | C) REVISE THE BUILDING EXPOSURE. ACCORDING TO SEC. | | | R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL THIS BUILDING IS | | | LOCATED IN EXPOSURE "C" NOT EXPOSURE "B". REVISE AS | | | REQUIRED. | | | | | | ***NOTE: | | | ACCORDING TO PAGE 14 OF NOA 12-0716.18 SUBMITTED THE | | | FASTENING OF THE BASE SHEET REQUIRES SIMPLEX MEGA CAP | | | NAILS. PLEASE CONFIRM THAT USING THIS TYPE OF NAILS. | | | OTHERWISE, REVISION FEES AND NEW APPROVED ASSEMBLY | | | USING OTHER NAIL TYPE WILL BE REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PANS EXAMINER | | | DEVELOPMENT SERVICES. | | | (561)805-6712 |
|