2014-07-30 06:46:55PLUMBING PLAN REVIEW
 PERMIT: 14050254
 ADD: 109 N OLIVE AVE
 CONT: TRI-R CONSTRUCTION
 TEL: (772)336-6444
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: WED. JULY 30/ 2014
  
 ACTION: PLUMBING PROVISO
  
 THE PLANS (P-3) INDICATES A NEW GREASE INTERCEPTOR.
 THIS INTERCEPTOR IS TO BE PERMITTED UNDER A SEPARATE.
 THE NEW GREASE INTERCEPTOR IS TO BE SIZED USING UNDER
 THE 2010 FBC-PLUMBING CODE SECTION 1003.3.4 TOTAL FLOW
 RATE WITH RATE OF FLOW CONTROL (1003.3.4.2) OR CONCRETE
 VAULT TYPE INTERCEPTORS (TABLE 1003.5.1).
  
 THE CITY FOG INSPECTORS (FATS, OILS & GREASE) MONITOR
 ALL GREASE INTERCEPTORS TO VERIFY COMPLIANCE WITH THE
 CITY?S MUNI CODE SEC. 90-126. PROHIBITIONS AND
 LIMITATIONS OF DISCHARGE.(7) MINERAL OIL IN EXCESS OF
 50 MG/L OR ANIMAL/VEGETABLE FATS, WAX, GREASE, OR OILS
 IN EXCESS OF 100 MG/L, WHETHER EMULSIFIED OR NOT; OR
 SUBSTANCES WHICH MAY SOLIDIFY OR BECOME VISCOUS AT
 TEMPERATURES LOWER THAN OR EQUAL TO 150 DEGREES
 FAHRENHEIT (65.56 DEGREES CELSIUS).
  
 IF THIS AMOUNT OF FATS, OILS OR GREASE IS EXCEEDED
 DURING INSPECTIONS THE REQUIRED MAINTENANCE & PUMP-OUT
 SCHEDULE WILL BE INCREASED TO KEEP IN COMPLIANCE WITH
 THE CITY'S MUNICIPAL CODE OF ORDINANCES.