| 2014-07-30 06:46:55 | PLUMBING PLAN REVIEW |
| | PERMIT: 14050254 |
| | ADD: 109 N OLIVE AVE |
| | CONT: TRI-R CONSTRUCTION |
| | TEL: (772)336-6444 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE: WED. JULY 30/ 2014 |
| | |
| | ACTION: PLUMBING PROVISO |
| | |
| | THE PLANS (P-3) INDICATES A NEW GREASE INTERCEPTOR. |
| | THIS INTERCEPTOR IS TO BE PERMITTED UNDER A SEPARATE. |
| | THE NEW GREASE INTERCEPTOR IS TO BE SIZED USING UNDER |
| | THE 2010 FBC-PLUMBING CODE SECTION 1003.3.4 TOTAL FLOW |
| | RATE WITH RATE OF FLOW CONTROL (1003.3.4.2) OR CONCRETE |
| | VAULT TYPE INTERCEPTORS (TABLE 1003.5.1). |
| | |
| | THE CITY FOG INSPECTORS (FATS, OILS & GREASE) MONITOR |
| | ALL GREASE INTERCEPTORS TO VERIFY COMPLIANCE WITH THE |
| | CITY?S MUNI CODE SEC. 90-126. PROHIBITIONS AND |
| | LIMITATIONS OF DISCHARGE.(7) MINERAL OIL IN EXCESS OF |
| | 50 MG/L OR ANIMAL/VEGETABLE FATS, WAX, GREASE, OR OILS |
| | IN EXCESS OF 100 MG/L, WHETHER EMULSIFIED OR NOT; OR |
| | SUBSTANCES WHICH MAY SOLIDIFY OR BECOME VISCOUS AT |
| | TEMPERATURES LOWER THAN OR EQUAL TO 150 DEGREES |
| | FAHRENHEIT (65.56 DEGREES CELSIUS). |
| | |
| | IF THIS AMOUNT OF FATS, OILS OR GREASE IS EXCEEDED |
| | DURING INSPECTIONS THE REQUIRED MAINTENANCE & PUMP-OUT |
| | SCHEDULE WILL BE INCREASED TO KEEP IN COMPLIANCE WITH |
| | THE CITY'S MUNICIPAL CODE OF ORDINANCES. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |