2014-05-09 11:37:032010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 1) SHOW THE LOCATION OF THE EXISTING METER AND CIRCUIT
 BREAKER PANEL. CITY AMENDMENTS 107.2.1 AND NEC
  
 2) SUBMIT LOAD CALCULATIONS AND A PANEL SCHEDULE. NEC
 220.40 AND NEC 408.4
  
 3) SHOW COMPLIANCE WITH NEC 210.11 (C) (3) FOR THE
 REQUIRED 20 AMP BATHROOM CIRCUIT.
  
 4) SHOW COMPLIANCE WITH NEC 210.8 (A) (1), (2) AND (3)
 FOR GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION.
  
 5) SHOW COMPLIANCE WITH NEC 210.12 FOR ARC-FAULT
 PROTECTION.
  
 6) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER-RESISTANT
 RECEPTACLES.
  
 7) SHOW COMPLIANCE WITH NEC 210.52 (A) (1) FOR
 RECEPTACLE SPACING.
  
 8) SHOW COMPLIANCE WITH NEC 210.52 (D) AND (E) (1) FOR
 BATHROOM AND OUTDOOR RECEPTACLE OUTLETS.
  
 9) SHOW COMPLIANCE WITH NEC 210.70 (A) (1), (2) AND (3)
 FOR REQUIRED INTERIOR AND OUTDOOR LIGHTING OUTLETS.
  
 10) THE NAME AND LICENSE NUMBER OF THE PERSON
 RESPONSIBLE FOR THE DESIGN IS REQUIRED ON THE
 ELECTRICAL PLANS. CITY AMENDMENTS 107.2.1
  