| Date |
Text |
| 2014-08-25 15:53:04 | BUILDING PLAN REVIEW |
| | PERMIT: 14050097 |
| | ADD: 8100 IBIS BLVD |
| | CONT:THE WEITZ CO. |
| | TEL: (561)686-5511 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE:FRI. AUG. 25/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) COMPLIED. |
| | 2) COMPLIED. |
| | |
| | 3) COMPLIED. |
| | |
| | 4A) 3RD REQUEST. 0173-P304 RISER E GREASE WASTE, THE |
| | PLANS INDICATE THE GREASE WASTE FROM KITCHENS # 135 & |
| | #245, THE PLANS INDICATE A 4 " GREASE WASTE WITH A 184 |
| | DFU'S TABLE 710.1.1 FOR A 4" BUILDING DRAIN AT A 1/8 |
| | INCH SLOPE WILL HANDLE 180 DFU'S WHERE AS AT A 1/4 |
| | SLOPE THEY DRAIN WILL HANDLE 216 DFU'S. THE NEW |
| | REVISION DOES STATE THE INSTALLATION OF (3) 1600 GALLON |
| | GREASE INTERCEPTORS. FOR A CONCRETE VAULT TYPE |
| | INTERCEPTOR THE FBC-P TABLE 1003.5.1 IS THE SIZING |
| | TABLE TO BE USED FOR THIS TYPE OF APPLICATION. |
| | (S) ? (GS) ? (HR/12) ? (LF) = EFFECTIVE CAPACITY OF |
| | GREASE INTERCEPTOR IN GALLONS. |
| | |
| | PLEASE NOTE THE GREASE INTERCEPTOR DOES REQUIRE A |
| | SEPARATE PERMIT , IF THE SLOPE ISSUE IS RESOLVED WE |
| | WILL BW ABLE TO PASS THE PLUMBING PERMIT WITH A PROVISO |
| | THAT THE GREASE INTERCEPTOR SIZING ISSUE TO BE REVIEWED |
| | UNDER THE SEPARATE INTERCEPTOR PERMIT. |
| | |
| | 4B)COMPLIED. |
| | |
| | 4C) COMPLIED. |
| | |
| | 5) COMPLIED. |
| | |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |