| Plan Review Notes For Permit 14050037 |
| Permit Number |
14050037 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-05-01 15:49:55 | PROVIDE PRODUCT INFORMATION FOR FLOORING OR FLOORING | | | UNDERLAYMENT DEMONSTRATING COMPLIANCE WITH | | | FBC 603.1 FLAME SPREAD -THERMAL AND ACOUSTICAL | | | INSULATION, OTHER THAN FOAM PLASTICS, HAVING A FLAME | | | SPREAD INDEX OF NOT MORE THAN 25. | | | EXCEPTIONS: | | | 1. INSULATION PLACED BETWEEN TWO LAYERS OF | | | NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING | | | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX | | | OF NOT MORE THAN 100. | | | 2. INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND | | | SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE | | | ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN | | | 200. | | | | | | FBC 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | |
|