| 2014-05-20 15:46:42 | ELECTRICAL PROVISOS FOR PERMIT 14041097 | | | 1. AS PER NEC300.5(B), THE INTERIOR OF AN UNDERGROUND | | | (OR IN CONCRETE SLAB) RACEWAY SHALL BE CONSIDERED A WET | | | LOCATION; ALL CONDUCTORS WITHIN THE RACEWAY SHALL BE | | | LISTED ACCORDINGLY. | | | 2. AS PER NEC 314.27, BOXES IN THE CEILING FOR HANGING | | | LUMINARIES SHALL BE DESIGNED TO SUPPORT MINIMUM 50#. | | | 3. NEC 210.52, HAS SPECIFIC OUTLET SPACING | | | REQUIREMENTS. | | | 4. SEE SUGGESTED 3WAY SWITCHING AS MARKED ON PLANS | | | | | | THESE PLANS WERE REVIEWED BY MIKE ALBARRAN, ELECTRICAL | | | PLANS EXAMINER | | | YOU ARE WELCOME TO REVIEW STATUS OR COMMENTS AT THE | | | FOLLOWING LINK: | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | ENTER YOUR PERMIT NUMBER (SEE SUBJECT LINE OF THIS | | | EMAIL FOR YOUR PERMIT #), CLICK ON THE PERMIT NUMBER, | | | AND THEN GO TO "PLAN REVIEWS" TO SEE YOUR COMMENTS (TAB | | | ABOVE THE SECOND PERMIT INFORMATION). | | | AFTER ISSUANCE, PLEASE CHECK YOUR PLAN CAREFULLY FOR | | | COMPLIANCE WITH ANY REDLINES, NOTES, PROVISOS, OR OTHER | | | PERMIT CONDITIONS. | | | FOR FURTHER ASSISTANCE, PLEASE FEEL FREE TO CONTACT ME. | | | I CAN BE REACHED AT 561-805-6718 OR | | | [email protected] |
|