2014-06-10 08:29:53****CORRECTIONS****
 ****COURTESY PLAN REVIEW (SUBMITTED VIA EMAIL)****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. IMPACT PROTECTION REQUIRED, FBC 1609.1.4.
  
 EXITS CANNOT BE BLOCKED BY IMPACT PROTECTION
 (SHUTTERS), SEE FBC 1003.6, MEANS OF EGRESS CONTINUITY.
  
 2ND REVIEW, RESPONSE IS THAT CUSTOMER HAS EXISTING
 SHUTTERS. PROVIDE A LIFE SAFETY PLAN TO SHOW EXIT DOORS
 BEING BLOCKED BY SHUTTERS AND PROVIDE A PERMIT NUMBER
 FOR THE SHUTTERS. THERE IS NO PROVISION IN THE FBC FOR
 SHUTTERS OVER MEANS OF EGRESS DOORS. THIS IS CONSIDERED
 BY THE BUILDING OFFICIAL ON A CASE BY CASE BASIS.
  
 2. ON THE PRODUCT APPROVAL, INDICATE OPTIONS PROPOSED.
 THIS APPEARS TO BE AN ENTRY/EXIT DOOR, SO AN ACCESSIBLE
 THRESHOLD IS REQUIRED FBC 2010 ACCESSIBILITY 404.2.5.
  
 2ND REVIEW, RESUB SHEET NOTED WHERE THIS INFORMATION
 CAN BE FOUND. PLEASE CIRCLE ON THE PRODUCT APPROVAL AS
 REQUESTED FOR BOTH PLAN REVIEW AND INSPECTION PURPOSES.
  
 3. EITHER INDICATE ON THE PRODUCT APPROVAL WHERE PANIC
 OR FIRE EXIT HARDWARE IS PROPOSED OR PROVIDE A LIFE
 SAFETY PLAN WHICH SHOWS WHY THIS WOULD NOT BE REQUIRED,
 FBC 1008.1.10.
  
 RESUBMITTAL FORM STATES THAT PANIC DEVICES ARE NOT
 NEEDED AS DOORS REMAIN OPEN. PROVIDE A LIFE SAFETY PLAN
 AS REQUESTED. THERE IS AN EXCEPTION IN THE CODE TO THE
 PANIC DEVICES, BUT THE EXCEPTION HAS REQUIREMENTS WHICH
 NEED TO BE SHOWN.
  
 NEW COMMENT:
  
 PLEASE RESUBMIT THROUGH THE FRONT COUNTER. AN EMAIL WAS
 SENT TO TWO DIFFERENT PEOPLE, NEITHER OF WHOM WERE THE
 PLAN REVIEWER WHO FAILED THE PLAN. NEW OR ADDITIONAL
 DOCUMENTS ARE REQUIRED. AT TIMES, SOME ITEMS MAY BE
 SUBMITTED VIA EMAIL UPON REQUEST UNDER CERTAIN
 CIRCUMSTANCES.
  
 IT IS SUGGESTED THAT YOU MAKE A RECORDS RESEARCH
 REQUEST FOR THE FLOOR PLAN OF THIS SPACE, PREFERABLY
 THE LIFE SAFETY PLAN. ON THIS PLAN, INDICATE LOCATION
 OF PROPOSED WORK. THIS PORTION MAY BE SENT VIA EMAIL TO
 ME FOR PRELIMINARY REVIEW.
  
 YOU CAN MAKE A PUBLIC RECORDS RESEARCH REQUEST TO:
 [email protected] OR [email protected]
  
  