| 2014-05-20 17:56:28 | PLUMBING PLAN REVIEW |
| | PERMIT:14040610 |
| | ADD: 300 COURTNEY LAKES |
| | CONT: LAGASSE POOL CONSTRUCTION |
| | TEL: (954)587-1000 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUESDAY MAY 20/2014 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE PROVIDE CODE COMPLIANCE WITH 2010 FBC-B |
| | 424.1.1 SIZING MAXIMUM GALLONS PER MINUTE? |
| | |
| | 2) PLEASE SHOW LOCATION AND COMPLIANCE WITH 2010 FBC-B |
| | 424.1.3.1.5 |
| | WALKWAYS SHALL BE PROVIDED BETWEEN THE POOL AND THE |
| | SANITARY FACILITIES, AND SHALL BE CONSTRUCTED OF |
| | CONCRETE OR OTHER NONABSORBENT MATERIAL HAVING A SMOOTH |
| | SLIP-RESISTANT FINISH FOR THE FIRST 15 FEET (4572 MM) |
| | OF THE WALKWAY MEASURED FROM THE NEAREST POOL WATER?S |
| | EDGE. A HOSE BIBB WITH A VACUUM BREAKER SHALL BE |
| | PROVIDED TO ALLOW THE DECK TO BE WASHED DOWN WITH |
| | POTABLE WATER. |
| | |
| | 3) PLEASE SHOW LOCATION AND COMPLIANCE WITH 2010 FBC-B |
| | 424.1.5.9 HOSE BIBBS. A HOSE BIBB WITH VACUUM BREAKER |
| | SHALL BE LOCATED IN THE EQUIPMENT ROOM OR AREA. |
| | |
| | 3) PLEASE SHOW LOCATION AND COMPLIANCE WITH 2010 FBC-B |
| | 424.1.6.1.4 HOSE BIBB. A HOSE BIBB WITH VACUUM BREAKER |
| | SHALL BE PROVIDED IN OR WITHIN 25 FEET (7620 MM) OF |
| | EACH RESTROOM TO ALLOW FOR EASE OF CLEANING. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |