| 2014-04-10 14:40:50 | BUILDING PLAN REVIEW |
| | PERMIT: 14040120 |
| | ADD: 2400 N FLAGLER DR |
| | CONT: BAYSHORE CONSTRUCTION |
| | TEL: (941)927-8565 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURSDAY APRIL 10/2014 |
| | ACTION: APPROVED, SEE B. O. COMMENTS |
| | REPAIR/ REPLACEMENT |
| | |
| | PROVISO: SHOW COMPLIANCE WITH THE FOLLOWING SECTION, |
| | 2010 FL ACCESSIBILITY CODE1005.2.1 HEIGHT. |
| | AT LEAST 25 PERCENT OF THE RAILINGS, GUARDS, OR |
| | HANDRAILS SHALL BE 34 INCHES (865 MM) MAXIMUM ABOVE THE |
| | GROUND OR DECK SURFACE. |
| | EXCEPTION: WHERE A GUARD COMPLYING WITH SECTIONS |
| | 1003.2.12.1 AND 1003.2.12.2 OF THE INTERNATIONAL |
| | BUILDING CODE (2000 EDITION) OR SECTIONS 1012.2 AND |
| | 1012.3 OF THE INTERNATIONAL BUILDING CODE (2003 |
| | EDITION) (INCORPORATED BY REFERENCE, SEE ?REFERENCED |
| | STANDARDS? IN CHAPTER 1) IS PROVIDED, THE GUARD SHALL |
| | NOT BE REQUIRED TO COMPLY WITH 1005.2.1. |
| | 1005.2.1.1 DISPERSION. |
| | RAILINGS, GUARDS, OR HANDRAILS REQUIRED TO COMPLY WITH |
| | 1005.2.1 SHALL BE DISPERSED THROUGHOUT THE FISHING PIER |
| | OR PLATFORM. |
| | ADVISORY 1005.2.1.1 DISPERSION. |
| | PORTIONS OF THE RAILINGS THAT ARE LOWERED TO PROVIDE |
| | FISHING OPPORTUNITIES FOR PERSONS WITH DISABILITIES |
| | MUST BE LOCATED IN A VARIETY OF LOCATIONS ON THE |
| | FISHING PIER OR PLATFORM TO GIVE PEOPLE A VARIETY OF |
| | LOCATIONS TO FISH. DIFFERENT FISHING LOCATIONS MAY |
| | PROVIDE VARYING WATER DEPTHS, SHADE (AT CERTAIN TIMES |
| | OF THE DAY), VEGETATION, AND PROXIMITY TO THE SHORELINE |
| | OR BANK. |
| | |