2014-05-23 07:36:48ELECTRICAL PROVISO:
  
 THIS PERMIT IS FOR THE INSTALLATION OF THE TELLER
 MACHINES ONLY. THE TELLER MACHINES SHALL COME COMPLETE
 WITH A FACTORY CORD AND PLUG INTO AN EXISTING
 RECEPTACLE.
  
 ALL THE ADDITIONAL WORK SHOWN ON THESE PLANS SUCH AS
 BUT NOT LIMITED TO ELECTRICAL PANELS, LIGHTING CONTROL
 PANELS, A STAND BY GENERATOR SYSTEM, LIGHTING,
 RECEPTACLES AND ALL RELATED CIRCUITRY. PLUS THE LOW
 VOLTAGE SCOPE, SUCH AS BUT NOT LIMITED TO THE
 INSTALLATION OF SECURITY CAMERAS, AND SPEAKERS HAS
 EITHER ALREADY BEEN COMPLETED ON OTHER PERMITS OR SHALL
 BE APPLIED FOR ON A SEPARATE PERMIT WITH A CLEAR SCOPE
 OF WORK.
  
 ADDITIONALLY, THE OPERATOR SHALL DEMONSTRATE COMPLIANCE
 WITH FBC-3112.2 AS FOLLOWS:
  
 EACH OPERATOR, OR OTHER PERSON RESPONSIBLE FOR AN
 AUTOMATED TELLER MACHINE PURSUANT TO SECTIONS 655.960
 THROUGH 655.965, SHALL PROVIDE LIGHTING DURING THE
 HOURS OF DARKNESS WITH RESPECT TO AN OPEN AND OPERATING
 AUTOMATED TELLER MACHINE AND ANY DEFINED PARKING AREA,
 ACCESS AREA AND THE EXTERIOR OF AN ENCLOSED AUTOMATED
 TELLER MACHINE INSTALLATION, AS FOLLOWS:
  
 1) THERE SHALL BE A MINIMUM OF 10 FOOT CANDLE (108 LUX)
 POWER AT THE FACE OF THE AUTOMATED TELLER MACHINE AND
 EXTENDING IN AN UNOBSTRUCTED DIRECTION OUTWARD 5 FEET
 (1.5 M).
  
 2) THERE SHALL BE A MINIMUM OF 2 FOOT CANDLE (21.5 LUX)
 POWER WITHIN 50 FEET (15.25 M) IN ALL UNOBSTRUCTED
 DIRECTIONS FROM THE FACE OF THE AUTOMATED TELLER
 MACHINE. IF THE AUTOMATED TELLER MACHINE IS LOCATED
 WITHIN 10 FEET (3 M) OF THE CORNER OF THE BUILDING AND
 THE AUTOMATED TELLER MACHINE IS GENERALLY ACCESSIBLE
 FROM THE ADJACENT SIDE, THERE SHALL BE A MINIMUM OF 2
 FOOT CANDLE (21.5 LUX) POWER ALONG THE FIRST 40
 UNOBSTRUCTED FEET (12 M) OF THE ADJACENT SIDE OF THE
 BUILDING.
  
 3) THERE SHALL BE A MINIMUM OF 2 FOOT CANDLE (12.5 LUX)
 POWER IN THAT PORTION OF THE DEFINED PARKING AREA
 WITHIN 60 FEET (18 M) OF THE AUTOMATED TELLER MACHINE.
  
 4) THE OPERATOR SHALL PROVIDE REFLECTIVE MIRRORS OR
 SURFACES AT EACH AUTOMATED TELLER MACHINE WHICH PROVIDE
 THE CUSTOMER WITH A REAR VIEW WHILE THE CUSTOMER IS
 ENGAGED IN USING THE AUTOMATED TELLER MACHINE.
  
  
  
  
  