Plan Review Notes
Plan Review Notes For Permit 14031119
Permit Number 14031119
Review Stop B
Sequence Number 1
Notes
Date Text
2014-04-25 15:03:56DEMONSTRATE COMPLIANCE WITH FBC-3112.2 AS FOLLOWS:
  
 EACH OPERATOR, OR OTHER PERSON RESPONSIBLE FOR AN
 AUTOMATED TELLER MACHINE PURSUANT TO SECTIONS 655.960
 THROUGH 655.965, SHALL PROVIDE LIGHTING DURING THE
 HOURS OF DARKNESS WITH RESPECT TO AN OPEN AND OPERATING
 AUTOMATED TELLER MACHINE AND ANY DEFINED PARKING AREA,
 ACCESS AREA AND THE EXTERIOR OF AN ENCLOSED AUTOMATED
 TELLER MACHINE INSTALLATION, AS FOLLOWS:
  
 1. THERE SHALL BE A MINIMUM OF 10 CANDLEFOOT (108 LUX)
 POWER AT THE FACE OF THE AUTOMATED TELLER MACHINE AND
 EXTENDING IN AN UNOBSTRUCTED DIRECTION OUTWARD 5 FEET
 (1.5 M).
  
 2. THERE SHALL BE A MINIMUM OF 2 FOOTCANDLE (21.5 LUX)
 POWER WITHIN 50 FEET (15.25 M) IN ALL UNOBSTRUCTED
 DIRECTIONS FROM THE FACE OF THE AUTOMATED TELLER
 MACHINE. IF THE AUTOMATED TELLER MACHINE IS LOCATED
 WITHIN 10 FEET (3 M) OF THE CORNER OF THE BUILDING AND
 THE AUTOMATED TELLER MACHINE IS GENERALLY ACCESSIBLE
 FROM THE ADJACENT SIDE, THERE SHALL BE A MINIMUM OF 2
 FOOTCANDLE (21.5 LUX) POWER ALONG THE FIRST 40
 UNOBSTRUCTED FEET (12 M) OF THE ADJACENT SIDE OF THE
 BUILDING.
  
 3. THERE SHALL BE A MINIMUM OF 2 FOOTCANDLE (12.5 LUX)
 POWER IN THAT PORTION OF THE DEFINED PARKING AREA
 WITHIN 60 FEET (18 M) OF THE AUTOMATED TELLER MACHINE.
  
 4. THE OPERATOR SHALL PROVIDE REFLECTIVE MIRRORS OR
 SURFACES AT EACH AUTOMATED TELLER MACHINE WHICH PROVIDE
 THE CUSTOMER WITH A REAR VIEW WHILE THE CUSTOMER IS
 ENGAGED IN USING THE AUTOMATED TELLER MACHINE.
  
 5. THE OPERATOR, OR OTHER PERSON RESPONSIBLE PURSUANT
 TO SECTIONS 655.960 THROUGH 655.965 FOR AN AUTOMATED
 TELLER MACHINE, SHALL ENSURE THAT THE HEIGHT OF ANY
 LANDSCAPING, VEGETATION OR OTHER PHYSICAL OBSTRUCTIONS
 IN THE AREA REQUIRED TO BE LIGHTED PURSUANT TO SECTION
 (2) FOR ANY OPEN AND OPERATING AUTOMATED TELLER MACHINE
 SHALL NOT EXCEED 3 FEET (914 MM), EXCEPT THAT TREES
 TRIMMED TO A HEIGHT OF 10 FEET (3 M) AND WHOSE
 DIAMETERS ARE LESS THAN 2 FEET (610 MM) AND MANMADE
 PHYSICAL OBSTRUCTIONS REQUIRED BY STATUTE, LAW, CODE,
 ORDINANCE OR OTHER GOVERNMENTAL REGULATION SHALL NOT BE
 AFFECTED BY THIS SECTION.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  