2014-04-11 08:35:34BUILDING PLAN REVIEW
 PERMIT: 14030980
 ADD: 3421 N AUSTRALIAN AVE
 CONT: TBD
 TEL: (561)502-1957 SOPHIA BARRETT
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 REVIEW
 DATE:
 ACTION: DENIED
  
 DEFINTIONS:
 313.2.1 FAMILY DAY CARE HOME.
 A FAMILY DAY CARE HOME IS A DAY CARE HOME IN WHICH MORE
 THAN THREE BUT FEWER THAN SEVEN CLIENTS RECEIVE CARE,
 MAINTENANCE AND SUPERVISION BY OTHER THAN THEIR
 RELATIVE(S) OR LEGAL GUARDIAN(S) FOR LESS THAN 24 HOURS
 PER DAY WITH NO MORE THAN TWO CLIENTS INCAPABLE OF
 SELF-PRESERVATION.
  
 313.2.2 GROUP DAY CARE HOME.
 A GROUP DAY CARE HOME IS A DAY-CARE HOME IN WHICH AT
 LEAST SEVEN BUT NOT MORE THAN 12 CLIENTS RECEIVE CARE,
 MAINTENANCE, AND SUPERVISION BY OTHER THAN THEIR
 RELATIVE(S) OR LEGAL GUARDIAN(S) FOR LESS THAN 24 HOURS
 PER DAY WITH NO MORE THAN THREE CLIENTS INCAPABLE OF
 SELF-PRESERVATION.
  
 THIS REVIEW IS BEING COMPLETED AS A GROUP HOME DAY
 CARE.
  
 1) PLEASE PROVIDE THE AGE OF THE CHILDREN THAT WILL BE
 UNDER YOUR SUPERVISION AND THE AMOUNT OF CLIENTS THAT
 WOULD BE INCAPABLE OF SELF-PRESERVATION. FBC-B 313.2.2.
  
 2) THE PLANS HAVE A CIRCLED AREA, IS THIS AREA (OFFICE)
 THE AREA OF THE GROUP DAY CARE HOME, IF SO WHERE ARE
 THE BATHROOM FACILITIES?
  
 1037.8.3
 IN GROUP DAY CARE HOMES, EVERY ROOM USED FOR SLEEPING,
 LIVING OR DINING PURPOSES SHALL HAVE AT LEAST TWO MEANS
 OF ESCAPE, AT LEAST ONE OF WHICH SHALL BE A DOOR OR
 STAIRWAY THAT PROVIDES A MEANS OF NONOBSTRUCTED TRAVEL
 TO THE OUTSIDE OF THE BUILDING AT STREET OR GROUND
 LEVEL. THE SECOND MEANS OF ESCAPE MAY BE A WINDOW
  
 436.2 CLOSET DOORS.
 EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CLIENTS CAN
 OPEN THE DOOR FROM INSIDE THE CLOSET.
  
 436.3 BATHROOM DOORS.
 EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT
 OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN
 EMERGENCY. THE OPENING DEVICE SHALL BE READILY
 ACCESSIBLE TO THE STAFF.
 IN ACCORDANCE WITH SECTION 1037.6.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676