| 2014-10-14 15:04:38 | 1) NEITHER THE COVERSHEET NOR ANY OF THE PLUMBING |
| | SHEETS PROVIDE THE REQUIRED MINIMUM FIXTURE COUNT PER |
| | THE 2010 FBC-PLUMBING, TABLE 403.1. |
| | 2) FOOTNOTE "G" OF TABLE 403.1 OF THE 2010 |
| | FBC-PLUMBING, REQUIRES A UNISEX BATHROOM IN MERCANTILE |
| | AND ASSEMBLY OCCUPANCIES WHERE AN AGGREGATE OF SIX OR |
| | MORE MALE AND FEMALE WATER CLOSETS ARE REQUIRED. |
| | 3) SUBMIT AN ENLARGED RESTROOM FLOOR PLAN FOR THE THE |
| | FIRST FLOOR. |
| | 4) THE RESTROOMS ON THE SECOND FLOOR SHALL COMPLY WITH |
| | THE FLORIDA ACCESSIBILITY CODE FOR BUILING |
| | CONSTRUCTION. |
| | 5) SHT. P-2 - THE 1ST FLOOR SANITARY PLAN IS ILLEGIBLE. |
| | SUBMIT A PLAN THAT IS CLEAR IN DETAIL. WPB AMEND. TO |
| | 2010 FBC SEC. 107.2.1. |
| | 6) THE 2ND FLOOR SANITARY ISOMETRIC HAS DRY VENTS FOR |
| | THE P-1 FIXTURES. EVERY DRY VENT CONNECTING TO A |
| | HORIZONTAL DRAIN SHALL CONNECT ABOVE THE CENTERLINE OF |
| | THE HORIZONTAL DRAIN PIPE PER THE 2010 FPC SEC.905.3. |
| | 7) THE FLOOR DRAINS ON THE FIRST FLOOR ARE NOT VENTED. |
| | FPC SEC.906.1. 901.2. |
| | 8) THE SANITARY LINE FOR FIXTURE P-1 ON THE FIRST FLOOR |
| | CONNECTS TO NOTHING. CLARIFY. |
| | 9) P-5 FIXTURES REQUIRE TRAPS. |
| | 10) THE SINGLE FLOOR DRAIN IN THE BAR AREA ON THE |
| | SECOND FLOOR IS NOT VENTED. FPC SEC.906.1 |
| | 11) THE NUMBER OF WATER CLOSETS BEING WET VENTED IN THE |
| | SECOND FLOOR RESTROOMS EXCEEDS THE NUMBER PERMITTED BY |
| | SEC.909 OF THE FPC. ALSO, URINALS ARE NOT PERMITTED ON |
| | A WET VENT. |
| | 12) BASED ON THE SHOWN OCCUPANT LOAD, THE MINIMUM |
| | NUMBER OF REQUIRED PLUMBING FIXTURES ARE AS FOLLOWS: |
| | A) 7 WATER CLOSETS, 4 LAVS FOR THE MALES |
| | B) 7 WATER CLOSETS, 4 LAVS FOR THE FEMALES |
| | C) 1 SERVICE SINK |
| | D) 2 DRINKING FOUNTAINS |
| | 13) CITY RECORDS ( PERMIT #03060274 ) SHOW THE SECOND |
| | FLOOR OF THIS BUILDING AS APARTMENTS, WHICH IS AN R-2 |
| | OCCUPANCY. THIS WILL BE CONSIDERED A CHANGE OF |
| | OCCUPANCY AND MUST COMPLY WITH CHAPT.9 , SECS. 902-913 |
| | OF THE 2010 FBC, EXISTING BUILDING CODE. |
| | |
| | PLUMBING PLAN REVIEW |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |