| 2014-04-14 15:47:34 | BUILDING PLAN REVIEW |
| | PERMIT: 14030562 |
| | ADD: 1875 PALM BCH LAKES # A09 |
| | CONT: TO BE DETERMINED |
| | TEL: (561)373-3902 / KARI |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: MONDAY APRIL 14/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) THE PLANS DO NOT HAVE THE STAMP OF APPROVAL OR |
| | LETTER FROM NEW ENGLAND DEVELOPMENT PALM BEACH OUTLETS |
| | SKYE GROUP TENANT COORDINATOR THAT THE PLANS AAND |
| | DESIGN ARE APPROVED. |
| | |
| | 2) PB OUTLET MALLS: |
| | A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| | CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| | CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| | PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| | CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| | HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| | WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| | DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND |
| | NOTARIZED. |
| | |
| | 3A) THE PLANS, LIFE SAFETY SHEET A1.0 DO NOT PROVIDE |
| | THE MINIMUM TYPE OF CONSTRUCTION, SHELL PERMIT IS TYPE |
| | IIB. 2010 FBC-B TABLE 503. |
| | |
| | 3B) THE PLANS, LIFE SAFETY SHEET A1.0 ARE INDICATING |
| | THEY ARE TAKING AREA INCREASES FOR FIRE SPRINKLERS, THE |
| | INDEX AND PLANS FAIL TO CONTAIN FIRE SPRINKLER & FIRE |
| | ALARM PLANS WITHIN THIS SET. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | (5) . FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: |
| | EARLY WARNING SMOKE EVACUATION SYSTEMS |
| | SCHEMATIC FIRE SPRINKLERS |
| | STANDPIPES |
| | PRE-ENGINEERED SYSTEMS |
| | RISER DIAGRAM |
| | |
| | 3C) THE LIFE SAFETY PLANS DO NOT PROVIDE ANY DETAILS |
| | FOR COMPLIANCE WITH : |
| | 2010 FBC- ACCESSIBILITY CODE. |
| | 904.3 CHECK-OUT AISLES. |
| | CHECK-OUT AISLES SHALL COMPLY WITH 904.3. |
| | 904.3.1 AISLE. |
| | AISLES SHALL COMPLY WITH 403. |
| | 904.3.2 COUNTER. |
| | THE COUNTER SURFACE HEIGHT SHALL BE 38 INCHES (965 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. THE TOP OF |
| | THE COUNTER EDGE PROTECTION SHALL BE 2 INCHES (51 MM) |
| | MAXIMUM ABOVE THE TOP OF THE COUNTER SURFACE ON THE |
| | AISLE SIDE OF THE CHECK-OUT COUNTER |
| | |
| | 904.4 SALES AND SERVICE COUNTERS. |
| | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| | SERVICE COUNTER TOP. |
| | |
| | 4) THE TENANT BUILD OUT VALUE IS LOW AT $18.64 DOLLARS |
| | / SQ FT. W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF |
| | PERMIT FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, |
| | MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS |
| | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID |
| | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE |
| | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 5) SHEET A2.2 INDICATES THE USE OF A X-RAY MACHINE IN |
| | ROOM 128 THERE DOES NOT APPEAR TO BE ANY SHIELDING OF |
| | WALLS NOR IS THERE A DOOR. FBC-B 435.5.1. SHIELDING. |
| | |
| | 6) SHEET A5.0 CURB DETAILS PLEASE SHOW COMPLIANCE WITH |
| | FBC-B 1509.7 MECHANICAL UNITS. ROOF MOUNTED MECHANICAL |
| | UNITS SHALL BE MOUNTED ON CURBS RAISED A MINIMUM OF 8 |
| | INCHES (203 MM) ABOVE THE ROOF SURFACE, OR WHERE |
| | ROOFING MATERIALS EXTEND BENEATH THE UNIT, |
| | |
| | 7) ALL ARCHITECTURAL SHEETS ARE COPIES OF THE ORIGINAL |
| | SIGNATURE, ALL SIGNATURES ARE IDENTICAL AND PIXOLATED. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | FL ADMIN CODE 61G16.003 ARCHITECTS |
| | |
| | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |