| Date |
Text |
| 2014-03-14 09:21:15 | BUILDING PLAN REVIEW |
| | PERMIT: 14030448 FOUNDATION PERMIT |
| | MASTER: 14011102 |
| | ADD: 1715 PALM BEACH LAKES |
| | RED ROBIN GOURMET BURGERS & BREWS |
| | CONTRACTOR: TO BE DETERMINED |
| | CONTACT: A & J |
| | TEL: (561) 373-3902 KARI |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. MARCH 14 /2014 |
| | ACTION: DENIED |
| | |
| | 1) DISCREPANCIES IN PLANS THE ARCHITECTURAL SHEETS |
| | DETAILS 1-3/ A4.1 SHOWS THE USE OF 2 INCH RIGID |
| | INSULATION AT THE STEM WALL LOCATION AS WELL AS UNDER |
| | THE SLAB. THE STRUCTURAL SHEET S1.0 INDICATES DETAIL 1/ |
| | S3.0, THIS DETAIL DOES NOT INDICATE THE USE OF FOAM |
| | INSULATION BENEATH THE SLAB. 2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, 2010 EDITION 107.2.1.3 ADDITIONAL |
| | INFORMATION PLANS TO BE CORRELATED TO PROVIDE THE SAME |
| | DETAILS. |
| | |
| | 2) THE ARCHITECTURAL SHEET A2.0 PROVIDES DETAILS 1-3/ |
| | A4.1 THESE DETAILS SHOW A SECONDARY SLAB IN THE DINING |
| | ROOM WHICH NONE OF THE STRUCTURAL SHEETS INDICATE, |
| | AGAIN A DISCREPANCY IN PLANS. 2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, 2010 EDITION 107.2.1.3 ADDITIONAL |
| | INFORMATION PLANS TO BE CORRELATED TO PROVIDE THE SAME |
| | DETAILS BETWEEN THE AARCHITECTURAL SHEETS AND |
| | STRUCTURAL SHEETS. |
| | |
| | 3) IT APPEARS ALL OF THE DINING ROOM IS POURED WITH A |
| | SECONDARY SLAB BUT THE KITCHEN AREA HAS A SINGLE SLAB. |
| | SHEET A2.0 HAS (3) DETAILS |
| | 1,2 & 6/ A6.0 SHOW THE ELEVATION CHANGE BETWEEN THE |
| | DINING ROOM FINISH FLOOR AND KITCHEN FLOOR. SHEET A2.0 |
| | DOES NOT INDICATE A CHANGE IN GRADE BETWEEN THE 2 |
| | FLOORS, NOR IS THERE ELEVATION MARKERS PROVIDING WHAT |
| | THE ELEVATION CHANGE IS? PLEASE PROVIDE COMPLIANCE |
| | WITH: |
| | |
| | FBC-B 1003.5. WHERE CHANGES IN ELEVATION OF LESS THAN |
| | 12 INCHES (305 MM) EXIST IN THE MEANS OF EGRESS, SLOPED |
| | SURFACES SHALL BE USED. WHERE THE SLOPE IS GREATER THAN |
| | ONE UNIT VERTICAL IN 20 UNITS HORIZONTAL (5-PERCENT |
| | SLOPE), RAMPS COMPLYING WITH SECTION 1010 SHALL BE |
| | USED. WHERE THE DIFFERENCE IN ELEVATION IS 6 INCHES |
| | (152 MM) OR LESS, THE RAMP SHALL BE EQUIPPED WITH |
| | EITHER HANDRAILS OR FLOOR FINISH MATERIALS THAT |
| | CONTRAST WITH ADJACENT FLOOR FINISH MATERIALS. |
| | |
| | 2010 FL ACCESSIBILITY CODE: 405.1 GENERAL. |
| | RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY WITH 405. |
| | 405.2 SLOPE. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT |
| | STEEPER THAN 1:12. |
| | 405.5 CLEAR WIDTH. THE CLEAR WIDTH OF A RAMP RUN AND, |
| | WHERE HANDRAILS ARE PROVIDED, THE CLEAR WIDTH BETWEEN |
| | HANDRAILS SHALL BE 36 INCHES (915 MM) MINIMUM. |
| | 405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE TOP |
| | AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL COMPLY |
| | WITH 405.7. |
| | 405.7.3 LENGTH. THE LANDING CLEAR LENGTH SHALL BE 60 |
| | INCHES (1525 MM) LONG MINIMUM. |
| | 505 HANDRAILS. 505.1 GENERAL. HANDRAILS PROVIDED ALONG |
| | WALKING SURFACES COMPLYING WITH 403, REQUIRED AT RAMPS |
| | COMPLYING WITH 405. |
| | |
| | 4) THE FOUNDATION PLANS DO NOT INDICATE HOW THEY ARE |
| | GOING TO COMPLY WITH 2010 FBC-B 1816.1 NOR 2603.8 FOAM |
| | INSULATION INSULATION USED BELOW GRADE, I'VE SPOKEN |
| | WITH THE DESIGNER OF RECORD ABOUT THIS AND APPARENTLY |
| | THIS INFORMATION IS INCORPORATED WITH IN THE DRAWINGS |
| | SPEC SHEETS THAT WAS NOT INCLUDED WITH THE FOUNDATION. |
| | |
| | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |